TY - JOUR AB - Background: On optical coherence tomography (OCT) scans of patients with inherited retinal diseases (IRDs), the outer nuclear layer (ONL) thickness measurement has been well established as a surrogate marker for photoreceptor preservation. Current automatic segmentation tools fail in OCT segmentation in IRDs, and manual segmentation is time consuming. Methods and Material: Patients with IRD and the availability of an OCT scan were screened for the present study. Additionally, OCT scans of patients without retinal disease were included, to provide training data for the artificial intelligence (AI). We trained a U-net based model on healthy patients and applied a domain adaption technique to IRD patients' scans. Results: We established an AI-based image segmentation algorithm that reliably segments the ONL in OCT scans of IRD patients. In a test dataset, the dice-score of the algorithm was 98.7%. Furthermore, we generated thickness maps of the full retinal thickness and the ONL layer for each patient. Conclusion: Accurate segmentation of anatomical layers on OCT scans plays a crucial role for predictive models linking retinal structure to visual function. The here-presented OCT image segmentation algorithm could provide the basis for further studies on IRDs. AU - Eckardt, F.* AU - Mittas, R. AU - Horlava, N. AU - Schiefelbein, J.* AU - Asani, B.* AU - Michalakis, S.* AU - Gerhardt, M.* AU - Priglinger, C.* AU - Keeser, D.* AU - Koutsouleris, N.* AU - Priglinger, S.* AU - Theis, F.J. AU - Peng, T. AU - Schworm, B.* C1 - 68982 C2 - 53790 TI - Deep Learning based retinal layer segmentation in optical coherence tomography scans of patients with inherited retinal diseases. JO - Klin. Monatsbl. Augenheilkd. PY - 2023 SN - 0023-2165 ER - TY - JOUR AB - Hintergrund Spurenelemente können über oxidativen Stress vermittelte molekulare Interaktionen in die Pathogenese der Glaukomerkrankung eingreifen. Vor allem für das Spurenelement Selen (Se) wird eine Mitbeteiligung postuliert. Der Selengehalt im Serum wird unter anderem über die Ernährung gesteuert und unterliegt damit kulturellen und ethnischen Variabilitäten. Das Ziel der vorliegenden Studie war es, den Serumselenspiegel bei Patienten mit primärem Offenwinkelglaukom (pOWG) im Vergleich zu einer Kontrollgruppe zu analysieren. Diese Ergebnisse der vorliegenden deutschen Kohorte wurden auf mögliche Alters- und Gendereffekte hin untersucht sowie ins Verhältnis zu der bislang einzig beschriebenen Kohorte in den US gesetzt. Material und Methoden Die Selenkonzentration wurde von 39 Serumproben (22 pOWG, 17 Kontrollen) anhand der Inductively coupled Plasma-sector Field Mass Spectrometry (ICP-sf-MS) analysiert. Die statistische Analyse umfasste eine Kovarianz-, Perzentilenregressions-, Alters- und Genderanalyse. Ergebnisse Die Serumselenkonzentration (Ls-mean) betrug 134,86 µg/l für Patienten mit pOWG und 132,02 µg/l für die Kontrollgruppe. Der Serumselengehalt zwischen diesen beiden Gruppen zeigte keinen signifikanten Unterschied (p > 0,05). Jedoch war ein dezenter Alters- und Gendereffekt zu beobachten. Die Quantilanalyse erbrachte eine Reduktion der 1. Serumselenquantile mit ansteigendem Alter bei den Patienten mit pOWG im Gegensatz zu den Kontrollprobanden. Die Odds Ratio der 1. Quantile betrug 1,3 (jeweils in Bezug zur 2. und 3. Quantile). Zusammenfassung Der Serumselengehalt von Patienten mit pOWG zeigte sich als ca. halb so hoch wie der publizierte Wert der US-Literaturkohorte (Glaukom 209,11 ng/ml; Kontrolle 194,45 ng/ml). Zusätzlich war ein leichter Alters- und Gendereffekt zu beobachten. AU - Lucio, M. AU - Fick, A.* AU - Michalke, B. AU - Laemmer, R.* AU - Hosari, S.* AU - Hohberger, B.* C1 - 61413 C2 - 50236 CY - Rudigerstr 14, D-70469 Stuttgart, Germany SP - 326-330 TI - Selenspiegel bei Glaukompatienten: eine Pilotstudie. JO - Klin. Monatsbl. Augenheilkd. VL - 239 IS - 3 PB - Georg Thieme Verlag Kg PY - 2022 SN - 0023-2165 ER - TY - JOUR AB - Background: For an implemented ophthalmological screening within a German long-term cohort study (National Cohort) simple and effective methods for an examination of visual acuity and for non-mydriatic retina photografies should be evaluated. Furthermore standard operating-procedures (SOP) should be developed. Methods: In the years 2011 and 2012 pinhole visual acuity measurements and automated retina photographies (DRS, CenterVue S. p. a., Padua, Italy) were made at three different epidemiological study centers within Germany. Furthermore, anterior segment images were taken by the camera. Standard operating procedures (SOP) regarding the ophthalmological screening were developed and evaluated within the study. The main question was whether it is possible to implement the screening methods within the National Cohort. Further main outcomes were quality and interpretability of the taken images. Results: 457 subjects (914 eyes) were examined within the investigation. Median VA was 0.8 for right and left eyes (p > 0.42). Image quality of the photographies was good in 491 cases (54 %), fair in 239 cases (26 %) and bad in 179 cases (20 %). The usability of the images was without limitations in 686 cases (75 %), limited in 152 cases (17 %) and not given in 71 cases (8 %). Increasing age of the subjects was slightly correlated with decreasing image quality (r = 0.26) and decreasing image usability (r = 0.2). Anterior segment photographies were usable in 176 eyes (56 %). Conclusion: The developed screening method fulfilled the specifications of the National Cohort. The used pinhole visual acuity examination was fast and cheap. Image quality and usability of the retina photographies could be improved with prolonged pupil recovery times. The quality of the anterior segment images could not fulfill the expectations and were taken out of the further examinations of the ophthalmological screening. The written SOP showed good acceptance within the investigators' daily routine. The ophthalmological screening within the National Cohort generates information (e. g., pathologies of the vessels or of the retina) which are useful not only from an ophthalmological point of view. AU - Leitritz, M.A.* AU - Hense, H.W.* AU - Schiefer, U.* AU - Nagel, M.* AU - Greiser, H.* AU - Linseisen, J. AU - Heid, I.M.* AU - Fischer, B.* AU - Thierry, S. AU - Bartz-Schmidt, K.U.* AU - Ueffing, M.* C1 - 27925 C2 - 32861 SP - 1238-1246 TI - Entwicklung und erste Anwendungserfahrungen einer schnellen und kostengünstigen ophthalmologischen Untersuchung für die Nationale Kohorte. JO - Klin. Monatsbl. Augenheilkd. VL - 230 IS - 12 PB - Thieme PY - 2013 SN - 0023-2165 ER - TY - JOUR AU - Rudolph, G. AU - Kalpadakis, P. AU - Haritoglou, C.* AU - Rivera, A.* AU - Weber, B.H.F.* C1 - 22009 C2 - 20555 SP - 590-596 TI - Mutationen im ABCA4-Gen in einer Familie mit Stargardtscher Erkrankung und Retinitis pigmentosa (STGD1/RP19). JO - Klin. Monatsbl. Augenheilkd. VL - 219 PY - 2002 SN - 0023-2165 ER -