TY - JOUR AB - Hazardous compounds such as airborne particulate polycyclic aromatic hydrocarbons (PAHs) and black carbon (BC) require special attention.The toxicological effects caused by the inhalation of such substances depend mainly on the concentration of each health relevant compound inhaled. In this feasibility study, portable aerosol samplers were utilised for the first time together with portable Aethalometers in different areas of a South African underground platinum mine.The preliminary results showed the highest mean toxicity equivalent (TEQ) values from 3.2 to 3.9 ng m(-3) in the mechanised mining areas, indicating the largest extent of diesel exhaust emissions at those sampling sites. Furthermore, very high mean equivalent black carbon (eBC) concentrations from 264 to 1 439 pg m(-3) were found in the same areas and give therefore, a cause of concern regarding occupational health aspects. In summary, both, the aerosol samplers and the Aethalometers delivered valuable data regarding the occupational exposure to airborne pollutants originating from combustion sources in mining activities. For such mining activities, the exposure to eBC was shown to be of greater concern than the exposure to PAHs. AU - Greiter, V. AU - Orasche, J. AU - Dragan, G.C.* AU - Jakobi, G. AU - Schnelle-Kreis, J. AU - Geldenhuys, G.-L.* AU - Forbes, P.B.C.* AU - Karg, E.W. AU - Breuer, D.* AU - Zimmermann, R.* C1 - 63591 C2 - 51557 CY - Vdi-platz 1, D-40468 Dusseldorf, Germany SP - 386-396 TI - Feasibility study of portable sampling techniques for combustion related airborne particulates in a platinum mine. JO - Gefahrstoffe Reinhalt. Luft VL - 81 IS - 9-10 PB - Springer-v D I Verlag Gmbh & Co Kg PY - 2021 SN - 0949-8036 ER - TY - JOUR AB - The Freising district council (Kreistag Freising) has initiated a measurement campaign to determine the concentrations of ultrafine particles (UFP) in the area around Munich Airport and the effects of the corona-related lockdown. In the framework of this measurement campaign, concentrations of ultrafine particles were determined with Discmini devices at seven locations in and around Munich Airport from June to August 2020 and, where available, compared with data recorded before the lockdown. The month-to-month values of UFP concentrations during the lockdown in spring 2020 correlates closely with the number of aircraft movements at Munich Airport. In February 2020 the average value was approximately 51,000 1/cm3, corresponding to 1,020 aircraft movements per day. During lockdown, in April 2020, UFP concentration dropped to around 7,000 1/cm³ with 68 aircraft movements per day– an approximately 95% reduction in UFP concentrations in parallel with the decrease in aircraft movements. As soon as the number of flights increased, UFP concentrations again increased. In the airport downwind plume, the UFP concentration is strongly correlated with the distance between the measurement location and the airport. Even with the significantly reduced numbers of flights during the lockdown, 1.5 times higher UFP concentration was measured at a distance of 11 km compared to the upwind concentration. Effective means of reducing UFP generated by air traffic are already available. These include: the desulfurization of kerosene, the electrification of the entire ground traffic at the airport including the use of emission-free aircraft tugs to haul the planes to and from the runway and the avoidance of unnecessary flights – especially flights that can be served by more environmentally friendly modes of transport (e. g. replacement of short-haul flights by rail journeys). AU - Herrmann, W. AU - Kendlbacher, R.* AU - Cyrys, J. AU - Rottmann, O.* C1 - 63699 C2 - 51638 SP - 458-469 TI - Effects of reduced aircraft movements after the COVID-19-shutdown on the concentration of ultrafine particles. JO - Gefahrstoffe Reinhalt. Luft VL - 81 IS - 11-12 PY - 2021 SN - 0949-8036 ER - TY - JOUR AB - Im Rahmen des interdisziplinä­ren Projekts „Smart Air Quality Network" (SmartAOnet) ist ein Messsystem für die Erfassung und Visualisierung der räumli­chen Verteilung von Luftschadstoffkonzentrationen im urbanen Raum entstanden. Die mehr als dreijährige Arbeit in SmartAOnet war darauf ausgerichtet, ein kostengünstiges Messnetz, das auf andere Städte übertragbar ist, mit Modell­rechnungen (Stadtklimamodell PALM4U) zur hochaufgelösten -räumlichen und zeitlichen -Bestimmung der Luftqualität in der Modellregion Augsburg zu verknüpfen. Kernbestandteil ist ein Datenhaltungssystem auf der Projektwebseitewww.smartaq.net/en/dashboard/, das sowohl Daten der Kon­zentrationen von PM10, PM2,5 und Partikelanzahlen dieses Messnetzes als auch weiterer Luftschadstoff-und meteorologi­scher Messungen, der Verkehrszählschleifen und urbaner Cha­rakteristika (unter anderem Gebäude-und Straßendaten) zu­sammenstellt und für jedermann zugänglich erfasst. Dasvielschichtige, heterogene Messnetz umfasst aktuell mehr als100 Middle-und Low-cost-Sensoren, zum Teil neu entwickeltestationäre Sensoren. Ergänzt wurden diese durch mobile Mes­sungen (Fahrräder, Messkarren), unbemannte Flugobjekte undFernerkundungssysteme für die dreidimensionale Erfassungder Verteilung von Luftschadstoffen und meteorologischen Pa­rametern auf einer Fläche von etwa 10 x 10 km, so dass bereitsmehrere hundert Millionen Datensätze erstellt werden konn­ten. Dazu hat auch die Bürgerbeteiligung durch Messungen mit Low-cost-Sensoren beigetragen. AU - Schäfer, K.* AU - Budde, M.* AU - Cyrys, J. AU - Emeis, S.* AU - Gratza, T.* AU - Grimm, H.* AU - Hank, M.* AU - Kowalski, M. AU - Pesch, M.* AU - Peters, A. AU - Philipp, A.* AU - Riedel, T.* AU - Riesterer, J.* AU - Schnelle-Kreis, J. AU - Tremper, P.* AU - Uhrner, U.* AU - Werhahn, J.* AU - Ziegler, V.* AU - Beigl, M.* C1 - 63238 C2 - 51277 SP - 353-361 TI - Hochaufgelöste Erfassung der urbanen Feinstaubbelastung mittels Messnetz aus kostengünstigen Sensoren und numerischen Simulationen. JO - Gefahrstoffe Reinhalt. Luft VL - 81 IS - 9-10 PY - 2021 SN - 0949-8036 ER - TY - JOUR AU - Walser-Reichenbach, S.M.* AU - Buters, J.T.M. AU - Gorny, R.* AU - Heederik, D.J.J.* AU - Heinze, S.* AU - Madsen, A.M.* AU - Niculita-Hirzel, H.* AU - Nowak, D.* AU - Pieckova, E.* AU - Plaza, M.* AU - Pogner, C.* AU - Raulf, M.* AU - Seidel, M.* AU - Straumfors, A.* AU - Tyrrel, S.* AU - Wouters, I.M.* AU - Jäckel, U.* AU - Herr, C.E.W.* C1 - 62299 C2 - 50606 SP - 435-436 TI - Bioaerosol expert forum: From “wrap up” to “cost action bioexposome”. JO - Gefahrstoffe Reinhalt. Luft VL - 80 IS - 11-12 PY - 2020 SN - 0949-8036 ER - TY - JOUR AB - A more accurate assessment of the workers' exposure to aerosols from semi-volatile organic compounds (SVOC) can be achieved through the simultaneous and separate sampling of both SVOC aerosol phases. From a toxicological point of view, it is important to analyse the exact vapour/particle distribution of such aerosols, since in case of inhalation both aerosol phases show different deposition characteristics in the respiratory tract. The objective of this study was to examine the usability of extruded monolithic carbonaceous denuders as a possible enhancement of the GGP sampler. Our study showed a high transmission efficiency (>= 98%) for one denuder and 1 to 3 mu m polystyrene latex particles as well as for SVOC droplets at a flow rate of 5 l/min. Furthermore, high adsorption efficiencies of about 97 % could be observed for a flow rate of 5 l/min and two denuders. However, at a higher flow rate of 10 l/min n-hexadecane vapour was adsorbed with a higher efficiency than diethylene glycol vapour. No considerable evaporation of approximately 1 and 2 mu m n-hexadecane droplets could be determined. Consequently, the characterised denuder could be used for an effective vapour/particle-partitioning of aerosols from non-polar alkanes with droplet diameters of 1 to 3 mu m at flow rates around 5 l/min. AU - Kohlmeier, V. AU - Dragan, G.-C. AU - Orasche, J. AU - Schnelle-Kreis, J. AU - Breuer, D.* AU - Zimmermann, R. C1 - 55849 C2 - 46606 SP - 47-54 TI - Monolithische kohlenstoffhaltige Denuder als Erweiterung der personengetragenen GGP-Sammler zur Probenahme luftgetragener Dampf/Partikel-Gemische. JO - Gefahrstoffe Reinhalt. Luft VL - 79 IS - 3 PY - 2019 SN - 0949-8036 ER - TY - JOUR AB - Gefahrstoffe- Reinhaltung der Luft - Ausgabe 6/2018 Charakterisierung von Partikelemissionen aus dem Trennschleifprozess von kohlefaserverstärktem Beton (Carbonbeton) Carbonbeton ist ein neu entwickelter Kompositbaustoff, dessen Bewehrung im Gegensatz zum klassischen Stahlbeton durch Carbonfasermaterial in Form von gebundenen Rovings als strukturierte Gelege erfolgt. Der bei der trennenden Bearbeitung des Carbonbetons freigesetzte Feinstaub enthält Zerkleinerungsprodukte des Fasermaterials. Zur umfassenden Untersuchung der gesundheitlichen Relevanz dieser Emissionen mit dem Fokus auf faserförmige Partikel wurde ein Analysensystem entwickelt, das ein Expositionssystem mit einem Trennstaubgenerator und einem Aerosolgenerator zur Erzeugung von Referenzaerosolen kombiniert. Weiterhin wurde das System um ein Partikelgrößenspektrometer und ein Massenspektrometer zur Charakterisierung der Partikel- und Gasphase der beim Trennen von Carbonbeton freigesetzten Staubaerosole erweitert. Erste Untersuchungen an vorliegenden Carbonbetonkonfigurationen zeigen, dass die erzeugten Stäube Anteile an der alveolengängigem und thorakalen Größenfraktion aufweisen und auch entsprechend negative Reaktionen bei exponierten Zellen hervorrufen. Allerdings kann in diesen Daten kein signifikanter Unterschied zwischen Stäuben aus dem Trennen von Reinbeton und Carbonbeton ausgemacht werden. Insbesondere die Analyse der freigesetzten Fasern ergab keine Hinweise auf gesundheitlich relevante Faserdimensionen im Sinne der Empfehlung der Weltgesundheitsorganisation. Characterization of particle emissions from cutting of carbon fiber reinforced concrete (Carbon concrete composite) Carbon concrete is a newly developed concrete composite construction material. The reinforcement of carbon concrete, in contrast to conventional reinforced concrete, is made of carbon fiber material in the form of bonded rovings as a structured layer. Upon cutting carbon concrete, the released fine dust contains components of the fiber material. In order to investigate the health relevance of these emissions, an analytical system was developed that combines a cell culture exposure system with a cutting dust generator and an aerosol generator producing reference aerosols. Furthermore, the system is equipped with a particle size spectrometer and a mass spectrometer to characterize the particle and gas phase of the released aerosols. First results for current carbon concrete configurations show that the generated dust exhibits relevant concentrations of particles in the alveolar and thoracic size fraction leading to corresponding adverse effects in exposed cells. However, in these data no significant difference between dust from the cutting of unreinforced concrete and carbon concrete can be identified. In particular, the analysis of the released fibers did not reveal any health-relevant fiber dimensions concerning the WHO recommendation.   AU - Hillemann, L.* AU - Stintz, M.* AU - Streibel, T.* AU - Zimmermann, R.* AU - Oeder, S. AU - Kasurinen, S. AU - Di Bucchianico, S. AU - Kanashova, T.* AU - Dittmar, G.* AU - Konzack, D.* AU - Grosse, S.* AU - Rudolph, A.* AU - Berger, M.* AU - Krebs, T.* AU - Saraji-Bozorgzad, M.R.* AU - Walte, A.* C1 - 54064 C2 - 45293 CY - Vdi-platz 1, D-40468 Dusseldorf, Germany SP - 230-240 TI - Charakterisierung von Partikelemissionen aus dem Trennschleifprozess von kohlefaserverstärktem Beton (Carbonbeton). JO - Gefahrstoffe Reinhalt. Luft VL - 78 IS - 6 PB - Springer-v D I Verlag Gmbh & Co Kg PY - 2018 SN - 0949-8036 ER - TY - JOUR AB - Aerosols from Semi-Volatile Organic Compounds (SVOCs) are usually partitioned in workplace air between the particulate and vapour phases. Personal samplers that are used for the occupational monito- ring of such aerosols should be able to trap both phases. In this study the dynamic changes in the partitioning of model SVOC aerosols are shown from an experimental point of view. Furthermore, the partitio- ning between filter and adsorber substrates of a personal sampler were compared for both aerosol sampling and spiking technique. In every comparison the spiking technique had more SVOC left on the filter substrate than by aerosol sampling. The difference between methods ranged from 13 to 52%. Based on these results, further measurements were undertaken to study the differences in evaporation rates of filters clogged with SVOC aerosol particles and that of spiked filters. AU - Dragan, G.-C. AU - Kohlmeier, V. AU - Breuer, D.* AU - Blaskowitz, M.* AU - Karg, E.W. AU - Zimmermann, R.* C1 - 52179 C2 - 43754 SP - 411-415 TI - On the challenges of measuring semi-volatile organic compound aerosols using personal samplers. JO - Gefahrstoffe Reinhalt. Luft VL - 77 IS - 10 PY - 2017 SN - 0949-8036 ER - TY - JOUR AB - The German Ultrafine Aerosol Network (GUAN) is a cooperative effort to scientifically explore the health and climate-related properties of the atmospheric aerosol in Germany. This work presents results on the basis of long-term observations of particle number size distributions and equivalent black carbon (eBC) between 2009 and 2014. At 17 observation sites, we found variations in mean total particle number concentration (diameter range 20 to 800 nm) between 850 and 10,500 p. cm(-3), and in eBC mass concentration between 0.17 and 2.8 mu g m(-3). Time series trend analyses yielded a significant relative decrease in eBC mass concentration (median: -5%/year) and in total particle number concentration (median: -4%/year), which is rather consistent at almost all sites over Germany. The consistent downward trends suggest that air quality-related societal efforts, which have been targeted mainly at reductions of total particle mass emissions, have a beneficial effect on ambient total particle number, ultrafine particle number, and eBC mass concentrations as well. AU - Birmili, W.* AU - Sun, J.* AU - Weinhold, K.* AU - Merkel, M.* AU - Rasch, F.* AU - Spindler, G.* AU - Wiedensohler, A.* AU - Bastian, S.* AU - Loeschau, G.* AU - Schladitz, A.* AU - Quass, U.* AU - Kuhlbusch, T.A.J.* AU - Kaminski, H.* AU - Cyrys, J. AU - Pitz, M. AU - Gu, J. AU - Peters, A. AU - Flentje, H.* AU - Meinhardt, F.* AU - Schwerin, A.* AU - Bath, O.* AU - Ries, L.* AU - Gerwig, H.* AU - Wirtz, K.* AU - Weber, S.* C1 - 48069 C2 - 39887 CY - Dusseldorf SP - 479-488 TI - Atmospheric aerosol measurements in the German Ultrafine Aerosol Network (GUAN) - part 3: Black carbon mass and particle number concentrations 2009 to 2014. JO - Gefahrstoffe Reinhalt. Luft VL - 75 IS - 11-12 PB - Springer-v D I Verlag Gmbh & Co Kg PY - 2015 SN - 0949-8036 ER - TY - JOUR AB - Aerosole schwerflüchtiger Verbindungen können an Arbeitsplätzen gleichzeitig als Tröpfchen und Dampf auftreten. Zu ihrer Probenahme ist ein System erforderlich, das beide Anteile gemeinsam sammelt. Das Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA) hat, basierend auf dem Probenahmekopf GSP, das miniaturisierte System GGP-Mini entwickelt. Es ist für die Probenahme schwerflüchtiger Stoffe gemäß DIN EN 13936, die gleichzeitig als Partikel und als Dampf auftreten können, ausgelegt. Validierungen und Praxismessungen mit Diethylenglykol (DEG) bei der Herstellung von Glasfasern bestätigten die bisherigen Ergebnisse: Als polarer Stoff unterliegt DEG einem ausgeprägten Einfluss von Luftfeuchte und Temperatur auf die Dampf-Tröpfchen-Verteilung. Die Praxismessungen zeigten, dass bei DEG-Aerosolen mit geringem Tröpfchenanteil die Ergebnisse einer kombinierten Dampf/Partikel-Probenahme mit deneneiner auf Dämpfe ausgelegten gut übereinstimmen. Aerosole mit höheren Tröpfchenanteilen am Arbeitsplatz zeigten Minderbefunde bei nur auf Dämpfe ausgelegter Probenahme. Hier ist eine kombinierte Partikel/Dampf-Probenahme erforderlich. AU - Breuer, D.* AU - Friedrich, C.* AU - Moehlmann, C.* AU - Dragan, G.-C. C1 - 47484 C2 - 40603 SP - 390-394 TI - Das miniaturisierte Probenahmesystem GGP-Minizur gleichzeitigen Erfassung von Dampf-Tröpfchen-Gemischen schwerflüchtiger Verbindungen : Ergebnisse von Labor- und Praxismessungen. JO - Gefahrstoffe Reinhalt. Luft VL - 75 IS - 10 PY - 2015 SN - 0949-8036 ER - TY - JOUR AB - Aerosole aus semivolatilen organischen Komponenten (SVOC, semi volatile organic compounds) stellen eine großeHerausforderung für die exakte Probenahme am industriellen Arbeitsplatz dar, da sie in variierenden Anteilen gleichzeitig in Gas(Dampf)- und Partikelphase vorliegen können. Die Gas-Partikel-Fraktionierung von SVOC hängt erheblich von den Probenahmebedingungen ab. Daher wurde hier die SVOC-Verdampfung theoretisch und experimentell nachvollzogen und das Ausmaß möglicher Probenahmeverluste in einer Klimakammer untersucht. Aerosoltröpfchen wurden aus n-Alkanenunterschiedlicher Kettenlänge (n-Tetradecan bis n-Eicosan) in unterschiedlichen Partikelgrößen generiert, mit partikelfreiem Stickstoff verdünnt und nach einer Stabilisierungszeit vergleichend mit zwei Methoden untersucht: einem Filter kombiniert mit einem Adsorber (offline) und einem optischen Partikelanalysator kombiniert mit einem Flammenionisationsdetektor (online). Die Vergleichsmessungen zwischen beiden Methoden zeigten eine gute Übereinstimmung bei der Gesamtmassenkonzentration, jedoch offline einen systematisch niedrigeren Partikel- und höheren Gasphasenanteil. Dieser Effekt sollte bei der Risikobewertung am Arbeitsplatz berücksichtigt werden: Die SVOC-Probenahme mit Filtern allein kann die Arbeitsplatzkonzentration signifikant unterschätzen. AU - Karg, E.W. AU - Dragan, G.-C. AU - Ferron, G.A. AU - Nordsieck, H.* AU - Blaskowitz, M.* AU - Friedrich, C.* AU - Kohlmeier, V. AU - Moehlmann, C.* AU - Schnelle-Kreis, J. AU - Stanglmaier, S. AU - Zimmermann, R.* AU - Breuer, D.* C1 - 46902 C2 - 39019 SP - 265-274 TI - Dynamisches Verhalten von Aerosolen aus semivolatilen Komponenten. JO - Gefahrstoffe Reinhalt. Luft VL - 75 IS - 7-8 PY - 2015 SN - 0949-8036 ER - TY - JOUR AB - During the determination of hazardous occupational aerosols from semi-volatile organic compounds (SVOCs), it is important to measure both particle and gas phase. A denuder is able to separate the gas from the particle phase of an aerosol, and the collected gas can be extracted and analysed independently. In this study Multichannel-PDMS-Denuders (MCD) were analysed with respect to their transmission and collection efficiency. The transmission efficiency was determined with polystyrene latex(PSL)-particles with a size of 0.3, 0.51, 0.75, 0.99, 1.54 and 1.93 mu m. Particle size-dependent transmission efficiencies between 93.3 to 86.7% for the 4 mm ID (inner diameter) liners (22 polydimethylsiloxane (PDMS) tubes) and 91.6 to 73.0% for the 3.29 mm ID liners (16 PDMS tubes) were measured. The experiments for the determination of the collection efficiency of MCD yielded for non-polar n-hexadecane a much higher sorption capacity (97% after 5 h, 85% after 24 h) than for polar diethylene glycol (94% after 15 min, 49% after 135 min). As a consequence, an approximately 30 times higher breakthrough volume was observed for n-hexadecane. AU - Kohlmeier, V. AU - Dragan, G.-C. AU - Karg, E.W. AU - Schnelle-Kreis, J. AU - Breuer, D.* AU - Forbes, P.B.C.* AU - Rohwer, E.R.* AU - Zimmermann, R. C1 - 47491 C2 - 40591 SP - 383-389 TI - The suitability of Multichannel-PDMS-Denuders for the gas-particle-partitioning of SVOCs. JO - Gefahrstoffe Reinhalt. Luft VL - 75 IS - 10 PY - 2015 SN - 0949-8036 ER - TY - JOUR AB - Der Beitrag zeigt Perspektiven für die Erforschung der gesundheitlichen Wirkung ultrafeiner Aerosolpartikel (UFP; Durchmesser < 100 nm) in der Außenluft auf. Obwohl UFP derzeit nicht Teil der gesetzlich geregelten Luftschadstoffe sind, legen ca. 50 epidemiologische Einzelstudien und toxikologische Erkenntnisse nahe, dass von UFP in der Außenluft eine schädliche Wirkung auf die menschliche Gesundheit ausgeht. In den kommenden Jahren werden in Deutschland einerseits große Mengen von Gesundheitsdaten im Rahmen der Nationalen Kohorte (NAKO) erzeugt, andererseits signifikante Datenmengen von UFP durch das GUAN-Messnetz (GUAN: German Ultrafine Aerosol Network) erhoben. Es wird vorgeschlagen, diese Ressourcen in Form dreier konkreter epidemiologischer Studientypen für die Gesundheitsforschung an UFP zu nutzen: a) Zeitreihenstudien zu Kurzzeiteffekten (Sterberegister, Notfalleinsätze, Krankenhauseinweisungen), b) Kohortenstudien zu Langzeiteffekten sowie c) Panelstudien zu Kurzzeiteffekten. AU - Birmili, W.* AU - Rückerl, R. AU - Hoffmann, B.* AU - Weinmayr, G.* AU - Schins, R.* AU - Kuhlbusch, T.A.J.* AU - Vogel, A.* AU - Weber, K.* AU - Franck, U.* AU - Cyrys, J. AU - Peters, A. C1 - 43523 C2 - 36014 CY - Dusseldorf SP - 492-500 TI - Ultrafeine Aerosolpartikel in der Außenluft: Perspektiven zur Aufklärung ihrer Gesundheitseffekte. JO - Gefahrstoffe Reinhalt. Luft VL - 74 IS - 11-12 PB - Springer-v D I Verlag Gmbh & Co Kg PY - 2014 SN - 0949-8036 ER - TY - JOUR AB - Volatile organic hazardous substances in the workplace air mainly exist in vapour form. To prevent the ambient pollution of working areas, volatile substances have been increasingly replaced with less volatile ones in the last few years. The droplets of these less volatile substances can remain in the air for a relatively long time and can no longer be neglected during sampling. The rules and regulations have been accordingly modified in the meantime. The paper reports on the GGP Mini sampling head developed at the Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA) which effectively meets the differing needs of particle and vapour sampling. It is designed for flow rates ranging from 0.066 to 0.5 l/m. Initial tests have shown a recovery rate of around 100% for the sum of vapour and droplets. The collection results for droplets and vapour by themselves vary greatly and only their sum can be determined reproducibly and with good repeatability. AU - Breuer, D.* AU - Friedrich, C.* AU - Moehlmann, C.* AU - Dragan, G.-C. C1 - 31701 C2 - 34670 CY - Dusseldorf SP - 129-134 TI - Entwicklung eines miniaturisierten Probenahmesystems zur gleichzeitigen Erfassung von Dampf-Tröpfchen-Gemischen bei schwerflüchtigen Verbindungen. JO - Gefahrstoffe Reinhalt. Luft VL - 74 IS - 4 PB - Springer-v D I Verlag Gmbh & Co Kg PY - 2014 SN - 0949-8036 ER - TY - JOUR AB - Zur Beurteilung des Einflusses von Emissionen aus der Gebäudeheizung auf die Feinstaubbelastung (PM10) in der Umgebungsluft wurden in der Heizperiode 2007/2008 Immissionsmessungen und Ausbreitungsrechnungen für den Raum Augsburg durchgeführt. Die Ausbreitungsrechnungen basieren auf Daten zu Emissionsintensität und -ort (Emissionszeitreihen), zur Orographie (Gebäude und Gelände) sowie zur Meteorologie. Die Ergebnisse der Ausbreitungsrechnung stimmen gut mit den gemessenen PM10-Konzentrationen überein. Ein wesentliches Ergebnis ist, dass die maximale Feinstaubkonzentration in einem Wohngebiet mit einer hohen Dichte an Holz-Einzelraumfeuerungsanlagen (Kaminöfen) doppelt so hoch ist wie im Stadtzentrum. Die Immissionsmessungen und die Ergebnisse der Ausbreitungsrechnung zeigen einen signifikanten Einfluss der häuslichen Holzverbrennung auf die Feinstaubkonzentration in der Umgebungsluft: Die höchste über die Heizperiode gemittelte Zusatzbelastung in einer Rechenzelle betrug 3,5 µg/m³. Der berechnete Heizperiodenmittelwert über alle Zellen mit Wohnbebauung mit einer mittleren Zusatzbelastung von mindestens 0,5 µg/m³ beträgt 1,32 µg/m³. Auf der Basis der Untersuchungsergebnisse kann der Einfluss der Holzverbrennung in mittelgroßen Städten abgeschätzt werden. AU - Kunde, R.* AU - Brandt, C.* AU - Dobmeier, B.* AU - Schnelle-Kreis, J. AU - Schmoeckel, G.* AU - Gaderer, M.* AU - Zimmermann, R. C1 - 6793 C2 - 29279 SP - 507-512 TI - Anteil der Partikel-Emissionen aus Holzverbrennung an PM10-Feinstaubimmissionen im städtischen Umfeld am Beispiel von Augsburg - Teil 2: Ausbreitungsrechnung. JO - Gefahrstoffe Reinhalt. Luft VL - 71 IS - 11-12 PB - Springer PY - 2011 SN - 0949-8036 ER - TY - JOUR AB - In den Heizperioden in den Jahren 2006 bis 2007 und 2007 bis 2008 wurden PM10-Konzentrationen in der Umgebungsluft sowie anorganische und organische Staubinhaltsstoffe gleichzeitig an bis zu acht Messstationen in Augsburg und in der näheren Umgebung ermittelt. Auf der Grundlage der Emissionsfaktoren für bestimmte Staubinhaltsstoffe wurde der Anteil von Primärpartikeln aus der Holzverbrennung an den PM10-Immissionen bestimmt. An einem verkehrsbelasteten Standort im Stadtzentrum stammten im Winter 2007/2008 im Mittel 3,4 µg/m³ des gesamten PM10 aus der Holzverbrennung (Bandbreite: 0,2 bis 15,2 µg/m³, 2 bis 30 %). Etwa die Hälfte der aus der Holzverbrennung stammenden PM10-Belastung ließ sich auf lokale Quellen zurückführen, die andere Hälfte auf Quellen außerhalb des Stadtgebiets. Ein weiteres Ergebnis der Untersuchung war, dass in einem Wohngebiet mit hoher Dichte an Holzfeuerungen die aus der Holzfeuerung resultierenden Partikelkonzentrationen um bis zu 3,7 µg/m³ höher lagen als im übrigen Stadtgebiet - bis zu einer Gesamtkonzentration von 9 µg/m³ im Tagesmittel. AU - Schnelle-Kreis, J. AU - Kunde, R.* AU - Schmoeckel, G.* AU - Abbaszade, G. AU - Gaderer, M.* AU - Diemer, J.* AU - Ott, H.* AU - Zimmermann, R.* C1 - 2107 C2 - 28212 SP - 203-209 TI - Anteil von Partikelemissionen aus Holzverbrennung an PM₁₀-Feinstaubimmissionen im städtischen Umfeld am Beispiel von Augsburg - Teil 1: Emissions- und Immissionsmessungen. JO - Gefahrstoffe Reinhalt. Luft VL - 70 IS - 5 PB - Springer-VDI-Verl. PY - 2010 SN - 0949-8036 ER - TY - JOUR AB - During the heating periods from 2006 to 2007 and 2007 to 2008 ambient PM(10), concentrations as well as inorganic and organic dust components were measured simultaneously at up to eight sampling sites in and near Augsburg. Based on the emission factors the contribution of primary particles from wood combustion to ambient PM(10) concentrations was calculated. In the city centre at a traffic-orientated site on average 3.4 mu g/m(3) of the total PM(10) originated from wood combustion (range 0.2 to 15.2 mu g/m(3), 2 to 30 %) in winter 2007/2008. About one half each of the PM(10) originated from local wood combustion and from wood combustion beyond the urban area. The results showed that in a residential area with high density of stoves the concentrations of particles from wood combustion were up to 3.7 mu g/m(3) higher than in the city centre - up to a total concentration of 9 mu g/m(3) in the daily average. AU - Schnelle-Kreis, J. AU - Kunde, R.* AU - Schmoeckel, G.* AU - Abbaszade, G. AU - Gaderer, M.* AU - Diemer, J.* AU - Ott, H.* AU - Zimmermann, R.* C1 - 32483 C2 - 35887 CY - Dusseldorf SP - 203-209 TI - Contribution of particulate emissions from wood combustion to ambient particulate matter in urban environments in Augsburg - Part 1: Emission and ambient air measurements. JO - Gefahrstoffe Reinhalt. Luft VL - 70 IS - 5 PB - Springer-v D I Verlag Gmbh & Co Kg PY - 2010 SN - 0949-8036 ER - TY - JOUR AB - Since the end of 2008 the German Ultrafine Aerosol Network (GUAN), an atmospheric observation network designed for long-term observations, is operational. The measurements are targeted at improving the description of the environmental aerosol (particulate matter), focussing on parameters that are relevant for human exposure but also climate effects. The measurements include sub-pm particle number size distributions, soot mass concentrations, and size-segregated chemical composition at a number of up to eleven observation sites. Specialised campaign measurements are added for a deeper understanding of the properties, sources, and processes related to ultrafine particles and soot. First observations from December 2008 and January 2009 illustrate the value of the network when characterising spatial and temporal effects in the atmospheric aerosol over an area such as Germany. AU - Birmili, W.* AU - Weinhold, K.* AU - Nordmann, S.* AU - Wiedensohler, A.* AU - Spindler, G.* AU - Müller, K.* AU - Herrmann, H.* AU - Gnauk, T.* AU - Pitz, M. AU - Cyrys, J. AU - Flentje, H.* AU - Nickel, C.* AU - Kuhlbusch, T.A.J.* AU - Loschau, G.* AU - Haase, D.* AU - Meinhardt, F.* AU - Schwerin, A.* AU - Ries, L.* AU - Wirtz, K.* C1 - 2246 C2 - 26628 SP - 137-145 TI - Atmospheric aerosol measurements in the German Ultrafine Aerosol Network (GUAN). JO - Gefahrstoffe Reinhalt. Luft VL - 69 IS - 4 PB - Springer PY - 2009 SN - 0949-8036 ER - TY - JOUR AB - Since the end of 2008, four experimental methods have been applied in the German Ultrafine Aerosol Network (GUAN) to characterize the light-absorbing and low-volatile components in the atmospheric aerosol known as "soot". These methods include: a) Multi-Angle Absorption Photometry (MAAP), b) Raman spectroscopy, c) thermographic analysis of samples from Berner impactors, and d) determination of the particle volume of the non-volatile fraction (at 300 °C) from number size distributions. The mass concentration of Graphitic Carbon (GC) measured by Raman spectroscopy correlated well with the light absorption coefficient measured by MAAP, and yielded GC absorption efficiencies in the range of 4.7 to 4.9 m² g-1. The comparison between elemental carbon (EC) mass concentrations from the thermographic method applied on Berner impactor samples and the light absorption measurement yielded a median EC absorption efficiency of 7.5 m2 g-1, but showed a considerable scattering within the data set. The particle volume of the non-volatile fraction compared relatively well with the light absorption measurement when assuming an effective particle density in the range of 0.8 to 1.1 g cm-3. The results suggested that the non-volatile particle residues in the sub-µm range are closely associated with light-absorbing carbon (LAC) and GC. Zusammenfassung Seit Ende 2008 werden im Deutschen Beobachtungsnetz für Ultrafeine Aerosolpartikel (GUAN - German Ultrafine Aerosol Network) kontinuierlich mehrere Messverfahren eingesetzt, die die Konzentration von Ruß in der Außenluft bestimmen. Diese sind im Einzelnen a) die Mehrwinkel-Absorptionsphotometrie (MAAP) als Lichtabsorptionsmessung, b) die Ramanspektroskopie, c) die thermographische Analyse von Partikelproben aus Berner-Impaktoren und d) die Bestimmung des Volumens aus Partikelanzahlgrößenverteilungen nach Verdampfung der bei 300 °C flüchtigen Verbindungen. Die ramanspektroskopisch gemessene Massenkonzentration von grafitischem Kohlenstoff (GC) korrelierte sehr gut mit dem MAAP-Absorptionskoeffizienten, woraus sich Absorptionseffizienzen zwischen 4,7 und 4,9 m² g-1 ergaben. Der Vergleich zwischen thermographisch bestimmten Massenkonzentrationen von elementarem Kohlenstoff (EC) für Berner-Impaktor-Proben und den MAAP-Absorptionskoeffizienten lieferte, bei beträchtlicher Streuung im Gesamtdatensatz, einen Medianwert der Absorptionseffizienz von 7,5 m2 g-1. Der Vergleich zwischen der Lichtabsorptionsmessung und dem Volumen der nichtflüchtigen Fraktion zeigte wieder eine relativ gute Korrelation, was zum vorläufigen Schluss führt, dass nicht flüchtige Bestandteile in Partikeln < 1 µm im engen Zusammenhang mit lichtabsorbierendem Kohlenstoff (LAC) und GC stehen. AU - Nordmann, S.* AU - Birmili, W.* AU - Weinhold, K.* AU - Wiedensohler, A.* AU - Mertes, S.* AU - Müller, K.* AU - Gnauk, T.* AU - Hermann, H.* AU - Pitz, M. AU - Cyrys, J. AU - Flentje, H.* AU - Ries, L.* AU - Wirtz, K.* C1 - 411 C2 - 26908 SP - 469-474 TI - Atmospheric aerosol measurements in the German Ultrafine Aerosol Network (GUAN) - part 2: Comparison of measurements techniques for graphitic, light-absorbing, and elemental carbon, and non-volatile particle volume under field conditions. JO - Gefahrstoffe Reinhalt. Luft VL - 69 IS - 11/12 PB - Springer PY - 2009 SN - 0949-8036 ER - TY - JOUR AB - Soil microbial communities are the key factor for a sustainable land use and preservation of soil quality. Bacteria, fungi and Archaea act as drivers for all major nutrient cycles and control plant development and health. Vice versa microbes in soil are highly influenced by the plants, as exsudates and litter provide important carbon sources for microbial activities. Therefore an assessment of effects of transgenic plants is only possible, if effects of classical cultivars are well understood. However, also parameters like temperature, soil type, fertilization and pesticide management and the season have an impact on soil microbiota. Therefore several factors have to be taken into account when monitoring strategies for the impact of genetically modified plants on soil quality should be developed. AU - Schloter, M. C1 - 942 C2 - 26463 CY - Düsseldorf SP - 395-399 TI - Bedeutung der Mikroflora für die Bodenqualität. Ableitung einer Monitoringstrategie zur Erfassung von Effekten genetisch veränderter Pflanzen auf Böden. JO - Gefahrstoffe Reinhalt. Luft VL - 69 IS - 10 PB - Springer-VDI PY - 2009 SN - 0949-8036 ER - TY - JOUR AB - A pronounced episode of long range transport of Saharan dust occurred from May 27 to June 1 2008. Elevated PM10 concentrations were observed as the particle cloud travelled from Southern France via parts of Italy, Switzerland and Austria to North-West Germany. The main transport of Saharan dust occurred aloft, leading to an uneven distribution of elevated PM10 concentrations at the ground. While most of Austria was affected near ground level, elevated PM10 burdens in Switzerland were only measured at two alpine stations. Chemical analyses and comparison of PM2.5/PM10 ratios revealed a change in the PM10 composition during the transport. While the high PM10 levels in the alpine region were mainly due to Saharan dust, visible in the high amount of PM10 and almost no change in PM2.5, the PM10 maxima in North-West Germany were mainly caused by secondary aerosol and a smaller but still significant share of dust particles. This is confirmed by maxima in the PM2.5 fraction occuring at the same time as the PM10 maxima and a high amount of ammonium nitrate and ammonium sulfate identified by chemical speciation. The exceedances of the European PM10 daily limit value during the episode can thus predominantly be assigned to natural sources in the Alpine region and in Bavaria, but only to a smaller part in North-Western Germany. AU - Bruckmann, P.* AU - Birmili, W.* AU - Straub, W.* AU - Pitz, M. AU - Gladtke, D.* AU - Pfeffer, U.* AU - Hebbinghaus, H.* AU - Wurzler, S.* AU - Olschewski, A.* C1 - 916 C2 - 26395 CY - Düsseldorf SP - 490-498  TI - An outbreak of Saharan dust causing high PM10 levels north of the Alps. JO - Gefahrstoffe Reinhalt. Luft VL - 68 IS - 11-12 PB - Springer-VDI PY - 2008 SN - 0949-8036 ER - TY - JOUR AU - Schramm, K.-W. AU - Lenoir, D. AU - Henkelmann, B. AU - Kettrup, A. C1 - 10169 C2 - 21503 SP - 113-118 TI - Die Dioxinbelastung beim Recycling von PVC und Elektronikschrott. JO - Gefahrstoffe Reinhalt. Luft VL - 62 PY - 2002 SN - 0949-8036 ER - TY - JOUR AU - Kirchner, M. AU - Braeutigam, S. AU - Römmelt, H. AU - Feicht, E. AU - Kettrup, A. C1 - 21460 C2 - 19577 SP - 383-388 TI - Ammoniakimmissionen aus dem Verkehrsbereich. JO - Gefahrstoffe Reinhalt. Luft VL - 60 PY - 2000 SN - 0949-8036 ER - TY - JOUR AU - Leisinger, K.-F.* AU - Lenoir, D. AU - Schramm, K.-W. C1 - 21378 C2 - 19494 SP - 217-222 TI - Abbau von polychlorierten Dibenzodioxinen und -furanen unter pyrolytischen, reduktiven Bedingungen nach dem GSU-Verfahren. JO - Gefahrstoffe Reinhalt. Luft VL - 60 PY - 2000 SN - 0949-8036 ER - TY - JOUR AU - Voigt, K. C1 - 21794 C2 - 19999 SP - 345-349 TI - Gefahrstoffinformationen im Internet. JO - Gefahrstoffe Reinhalt. Luft VL - 60 PY - 2000 SN - 0949-8036 ER -