Rothkamm, K.* ; Horn, S.* ; Scherthan, H.* ; Rößler, U.* ; de Amicis, A.* ; Barnard, S.* ; Kulka, U.* ; Lista, F.* ; Meineke, V.* ; Braselmann, H. ; Beinke, C.* ; Abend, M.*

Laboratory intercomparison on the γ-H2AX foci assay.

Radiat. Res. 180, 149-155 (2013)
Verlagsversion Forschungsdaten DOI PMC
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
The focus of the study is an intercomparison of laboratories' dose-assessment performances using the γ-H2AX foci assay as a diagnostic triage tool for rapid individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25-4 Gy) as well as blinded test samples (0.1-6.4 Gy) were incubated at 37°C for 2 and 24 h (repair time) and sent to the participants. The foci assay was performed according to protocols individually established in participating laboratories and therefore varied. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) of estimated doses relative to the actual doses was calculated and radiation doses were merged into four triage categories reflecting clinical relevance to calculate accuracy, sensitivity and specificity. First γ-H2AX based dose estimates were reported 7 h after sample receipt. Estimates were similarly accurate for 2 and 24 h repair times, providing scope for its use in the early phase of a radiation exposure incident. Equal accuracy was achieved by scoring 20, 30, 40 or 50 cells per sample. However, MAD values of 0.5-0.7 Gy and 1.3-1.7 Gy divided the data sets into two groups, driven mainly by the considerable differences in foci yields between calibration and blind samples. Foci yields also varied dramatically between laboratories, highlighting reproducibility issues as an important caveat of the foci assay. Nonetheless, foci counts could distinguish high- and low-dose samples in all data sets and binary dose categories of clinical significance could be discriminated with satisfactory accuracy (mean 84%, ±0.03 SEM). Overall, the results suggest that the γ-H2AX assay is a useful tool for rapidly screening individuals for significant exposures that occurred up to at least 24 h earlier, and may help to prioritize cytogenetic dosimetry follow-up.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
2.698
1.326
40
46
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter Radiation-exposure; Blood-lymphocytes; Residual Dna; Damage; Quantification; Radiotherapy; Biomarker; Skin; Ct
Sprache englisch
Veröffentlichungsjahr 2013
HGF-Berichtsjahr 2013
ISSN (print) / ISBN 0033-7587
e-ISSN 1938-5404
Zeitschrift Radiation Research
Quellenangaben Band: 180, Heft: 2, Seiten: 149-155 Artikelnummer: , Supplement: ,
Verlag Radiation Research Society
Verlagsort Lawrence
Begutachtungsstatus Peer reviewed
POF Topic(s) 30203 - Molecular Targets and Therapies
Forschungsfeld(er) Radiation Sciences
PSP-Element(e) G-501000-001
PubMed ID 23883318
Scopus ID 84882278526
Erfassungsdatum 2013-09-23