PuSH - Publikationsserver des Helmholtz Zentrums München

The dosage of small volumes for chromatographic quantifications using a drop-on-demand dispenser system.

Anal. Bioanal. Chem. 388, 1109-1116 (2007)
DOI PMC
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
A commercially available piezo-driven drop-on-demand dispenser was tested for its suitability for the preparation of analytical calibration standards and in a standard addition approach prior to quantitative ultra performance liquid chromatography (UPLC) analysis of homoserines. The reproducibility of the drop-on-demand dosing system was tested and the verification of the droplet volume was performed by preparing a series of 1.0 mg/L caffeine standard solutions from a 1,000.0 mg/L stock solution and analysis of the concentrations obtained by UPLC. The reproducibility was better than 1% relative standard deviation from measurement to measurement and the highest was 1.6% from day to day. The results were compared with the conventional way of generating standard solutions (pipetting). A gravimetric method and a photography-based method for the determination of the average single droplet volume were compared and found to be in very good agreement. The system was employed for the quantification of N-decanoyl homoserine by standard addition in bacterial culture supernatants containing this analyte. The agreement with conventional quantification techniques was high. The paper shows the feasibility of the approach with advantages in low sample and solvent volume consumption and very good reproducibility and reliability combined with easy usage.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
2.591
1.255
20
25
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter Piezo-driven drop-on-demand dispenser; Ultra performance liquid chromatography; Droplets; Dispenser; Calibration standards; N-Acyl homoserines
Sprache
Veröffentlichungsjahr 2007
HGF-Berichtsjahr 2007
ISSN (print) / ISBN 1618-2642
e-ISSN 1618-2650
Quellenangaben Band: 388, Heft: 5-6, Seiten: 1109-1116 Artikelnummer: , Supplement: ,
Verlag Springer
Verlagsort Heidelberg
Begutachtungsstatus Peer reviewed
Institut(e) Institute of Ecological Chemistry (IOEC)
PSP-Element(e) G-505100-007
Scopus ID 34547269689
PubMed ID 17549459
Erfassungsdatum 2007-08-28