PuSH - Publikationsserver des Helmholtz Zentrums München

Bay, E. ; Douplik, A.* ; Razansky, D.

Optoacoustic monitoring of cutting efficiency and thermal damage during laser ablation.

Lasers Med. Sci. 29, 1029-1035 (2013)
DOI PMC
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
Successful laser surgery is characterized by a precise cut and effective hemostasis with minimal collateral thermal damage to the adjacent tissues. Consequently, the surgeon needs to control several parameters, such as power, pulse repetition rate, and velocity of movements. In this study we propose utilizing optoacoustics for providing the necessary real-time feedback of cutting efficiency and collateral thermal damage. Laser ablation was performed on a bovine meat slab using a Q-switched Nd-YAG laser (532 nm, 4 kHz, 18 W). Due to the short pulse duration of 7.6 ns, the same laser has also been used for generation of optoacoustic signals. Both the shockwaves, generated due to tissue removal, as well as the normal optoacoustic responses from the surrounding tissue were detected using a single broadband piezoelectric transducer. It has been observed that the rapid reduction in the shockwave amplitude occurs as more material is being removed, indicating decrease in cutting efficiency, whereas gradual decrease in the optoacoustic signal likely corresponds to coagulation around the ablation crater. Further heating of the surrounding tissue leads to carbonization accompanied by a significant shift in the optoacoustic spectra. Our results hold promise for real-time monitoring of cutting efficiency and collateral thermal damage during laser surgery. In practice, this could eventually facilitate development of automatic cut-off mechanisms that will guarantee an optimal tradeoff between cutting and heating while avoiding severe thermal damage to the surrounding tissues.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Korrespondenzautor
Schlagwörter Optoacoustics; Cutting efficiency; Thermal damage; Laser ablation; Laser surgery; Shockwaves; Photoacoustic imaging; Diffuse-reflectance Spectroscopy; Soft-tissue Surgery; Yag Laser; In-vitro; Nd-yag; Co2-laser
ISSN (print) / ISBN 0268-8921
e-ISSN 1435-604x
Quellenangaben Band: 29, Heft: 3, Seiten: 1029-1035 Artikelnummer: , Supplement: ,
Verlag Springer
Verlagsort London
Nichtpatentliteratur Publikationen
Begutachtungsstatus Peer reviewed