PuSH - Publikationsserver des Helmholtz Zentrums München

Razansky, D. ; Rozental, A.* ; Müller, M.S.* ; Deliolanis, N. ; Jaffer, F.A.* ; Koch, A.W.* ; Ntziachristos, V.

Double-cladding-fiber-based detection system for intravascular mapping of fluorescent molecular probes.

Proc. SPIE 7894:78940K (2011)
Verlagsversion DOI
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
Early detection of high-risk coronary atherosclerosis remains an unmet clinical challenge. We have previously demonstrated a near-infrared fluorescence catheter system for two-dimensional intravascular detection of fluorescence molecular probes [1]. In this work we improve the system performance by introducing a novel high resolution sensor. The main challenge of the intravascular sensor is to provide a highly focused spot at an application relevant distance on one hand and a highly efficient collection of emitted light on the other. We suggest employing a double cladding optical fiber (DCF) in combination with focusing optics to provide a sensor with both highly focused excitation light and highly efficient fluorescent light collection. The excitation laser is coupled into the single mode core of DCF and guided through a focusing element and a right angle prism. The resulting side-fired beam exhibits a small spot diameter (50 μm) throughout a distance of up to 2 mm from the sensor. This is the distance of interest for intravascular coronary imaging application, determined by an average human coronary artery diameter. At the blood vessel wall, an activatable fluorescence molecular probe is excited in the diseased lesions. Next light of slightly shifted wavelength emits only in the places of the inflammations, associated with dangerous plaques [2]. The emitted light is collected by the cladding of the DCF, with a large collection angle (NA=0.4). The doublecladding acts as multimodal fiber and guides the collected light to the photo detection elements. The sensor automatically rotates and pulled-back, while each scanned point is mapped according to the amount of detected fluorescent emission. The resulting map of fluorescence activity helps to associate the atherosclerotic plaques with the inflammation process. The presented detection system is a valuable tool in the intravascular plaque detection and can help to differentiate the atherosclerotic plaques based on their biological activity, identify the ones that prone to rupture and therefore require more medical attention.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Korrespondenzautor
ISSN (print) / ISBN 0277-786X
e-ISSN 1996-756X
Konferenztitel Optical Fibers, Sensors, and Devices for Biomedical Diagnostics and Treatment XI
Konferzenzdatum January 22, 2011
Konferenzort San Francisco, California, USA
Zeitschrift Proceedings of SPIE
Quellenangaben Band: 7894, Heft: , Seiten: , Artikelnummer: 78940K Supplement: ,
Verlag SPIE
Nichtpatentliteratur Publikationen
Begutachtungsstatus Peer reviewed