Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
Dynamic shape factor of nonspherical aerosol particles in the diffusion regime.
Aerosol Sci. Technol. 12, 270-277 (1990)
Diffusional losses of monodisperse polysterene spheres and doublets from laminar aerosol flows and stagnant aerosols in cylindrical tubes were measured. The losses of spheres were used to determine their diameter (range 69-120 mm) and the volume equivalent diameter of their doublets. The losses of the doublets were used to determine their dynamic shape factor which for randomly oriented doublets was established to be 1.127 ± 0.085 for Knudsen numbers between 1.1 and 2.0. | Diffusional losses of monodisperse polystyrene spheres and doublets from laminar aerosol flows and stagnant aerosols in cylindrical tubes were measured. The losses of spheres were used to determine their diameter (range 69-120 nm) and the volume equivalent diameter of their doublets. The losses of the doublets were used to determine their dynamic shape factor which for randomly oriented doublets was established to be 1.127 ± 0.085 for Knudsen numbers between 1.1 and 2.0.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten
[➜Einloggen]
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
ISSN (print) / ISBN
0278-6826
e-ISSN
1521-7388
Zeitschrift
Aerosol Science and Technology
Quellenangaben
Band: 12,
Heft: 2,
Seiten: 270-277
Verlag
Taylor & Francis
Nichtpatentliteratur
Publikationen
Begutachtungsstatus
Peer reviewed
Institut(e)
Abteilung Biophysikalische Strahlenforschung