PuSH - Publikationsserver des Helmholtz Zentrums München

A 400 rad flash x ray system for pulse radiolysis.

Rev. Sci. Instruments 45, 650-652 (1974)
Verlagsversion DOI
Closed
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
The design and working principle of a flash x ray system are described. A two stage Marx generator is used, the charging voltage is 150 kV and the stored energy 1125 J. Anode and cathode are arranged coaxially. The anode consists of a tungsten coated aluminium tube of 20 mm i.d. into which the substances to be irradiated are placed. Measurements of electrical and radiation parameters are described. The x ray dose per pulse is 400 rad, the half width of the pulse is 0.2 μsec and the mean quantum energy is 44 keV. An example for the application of the system in microsecond pulse radiolysis is presented.
Impact Factor
Scopus SNIP
Altmetric
0.000
0.000
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Sprache englisch
Veröffentlichungsjahr 1974
HGF-Berichtsjahr 0
ISSN (print) / ISBN 0034-6748
e-ISSN 1089-7623
Quellenangaben Band: 45, Heft: 5, Seiten: 650-652 Artikelnummer: , Supplement: ,
Verlag American Institute of Physics (AIP)
Begutachtungsstatus Peer reviewed
Institut(e) Institut für Strahlenbotanik
Scopus ID 0016248342
Erfassungsdatum 1974-11-27