PuSH - Publikationsserver des Helmholtz Zentrums München

Zvarova, B.* ; Uhl, F.E.* ; Uriarte, J.J.* ; Borg, Z.D.* ; Coffey, A.L.* ; Bonenfant, N.R.* ; Weiss, D.J.* ; Wagner, D.E.

Residual detergent detection method for nondestructive cytocompatibility evaluation of decellularized whole lung scaffolds.

Tissue Eng. Part C Meth. 22, 418-428 (2016)
DOI
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
The development of reliable tissue engineering methods using decellularized cadaveric or donor lungs could potentially provide a new source of lung tissue. The vast majority of current lung decellularization protocols are detergent based and incompletely removed residual detergents may have a deleterious impact on subsequent scaffold recellularization. Detergent removal and quality control measures that rigorously and reliably confirm removal, ideally utilizing nondestructive methods, are thus critical for generating optimal acellular scaffolds suitable for potential clinical translation. Using a modified and optimized version of a methylene blue-based detergent assay, we developed a straightforward, noninvasive method for easily and reliably detecting two of the most commonly utilized anionic detergents, sodium deoxycholate (SDC) and sodium dodecyl sulfate (SDS), in lung decellularization effluents. In parallel studies, we sought to determine the threshold of detergent concentration that was cytotoxic using four different representative human cell types utilized in the study of lung recellularization: human bronchial epithelial cells, human pulmonary vascular endothelial cells (CBF12), human lung fibroblasts, and human mesenchymal stem cells. Notably, different cells have varying thresholds for either SDC or SDS-based detergent-induced cytotoxicity. These studies demonstrate the importance of reliably removing residual detergents and argue that multiple cell lines should be tested in cytocompatibility-based assessments of acellular scaffolds. The detergent detection assay presented here is a useful nondestructive tool for assessing detergent removal in potential decellularization schemes or for use as a potential endpoint in future clinical schemes, generating acellular lungs using anionic detergent-based decellularization protocols.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
1.420
0.892
36
49
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter Perfusion Decellularization; Anionic Surfactants; Methylene-blue; Re-cellularization; High-throughput; Acellular Human; Clinical-scale; Porcine Lungs; Stem-cells; Matrix
Sprache englisch
Veröffentlichungsjahr 2016
HGF-Berichtsjahr 2016
ISSN (print) / ISBN 1937-3384
e-ISSN 1937-3392
Quellenangaben Band: 22, Heft: 5, Seiten: 418-428 Artikelnummer: , Supplement: ,
Verlag Mary Ann Liebert
Verlagsort New Rochelle
Begutachtungsstatus Peer reviewed
POF Topic(s) 30503 - Chronic Diseases of the Lung and Allergies
Forschungsfeld(er) Lung Research
PSP-Element(e) G-551800-001
Erfassungsdatum 2016-07-22