PuSH - Publikationsserver des Helmholtz Zentrums München

Gradl, R.* ; Dierolf, M.* ; Hehn, L.* ; Günther, B.* ; Yildirim, A.Ö. ; Gleich, B.* ; Achterhold, K.* ; Pfeiffer, F.* ; Morgan, K.S.*

Propagation-based phase-contrast x-ray imaging at a compact light source.

Sci. Rep. 7:4908 (2017)
Verlagsversion DOI PMC
Open Access Gold
Creative Commons Lizenzvertrag
We demonstrate the applicability of propagation-based X-ray phase-contrast imaging at a laser-assisted compact light source with known phantoms and the lungs and airways of a mouse. The Munich Compact Light Source provides a quasi-monochromatic beam with partial spatial coherence, and high flux relative to other non-synchrotron sources (up to 10(10) ph/s). In our study we observe significant edge-enhancement and quantitative phase-retrieval is successfully performed on the known phantom. Furthermore the images of a small animal show the potential for live bio-imaging research studies that capture biological function using short exposures.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Korrespondenzautor
Schlagwörter In-vivo Assessment; Synchrotron-radiation; Tomography; Resolution; Fibrosis; Tissue; Mice
ISSN (print) / ISBN 2045-2322
e-ISSN 2045-2322
Zeitschrift Scientific Reports
Quellenangaben Band: 7, Heft: 1, Seiten: , Artikelnummer: 4908 Supplement: ,
Verlag Nature Publishing Group
Verlagsort London
Nichtpatentliteratur Publikationen
Begutachtungsstatus Peer reviewed