Borm, K.J.* ; Loos, M.* ; Oechsner, M.* ; Mayinger, M.C.* ; Paepke, D.* ; Kiechle, M.B.* ; Combs, S.E. ; Duma, M.N.
Acute radiodermatitis in modern adjuvant 3D conformal radiotherapy for breast cancer - the impact of dose distribution and patient related factors.
Radiat. Oncol. 13:218 (2018)
PurposeThis study was performed to evaluate skin toxicity during modern three-dimensional conformal radiotherapy (3D-CRT) and to evaluate the importance of dose distribution and patient related factors.Material and methodsThis study comprises 255 patients with breast cancer treated with tangential three-dimensional conformal radiotherapy (3D-CRT) after breast conserving surgery between 03/2012 and 05/2017. The median prescribed dose was 50.4Gy (range 50-50.4) and 92.2% of the patients received a sequential boost of 10-16Gy. Adverse skin toxicities (according to CTCAE v. 4.03 and the occurrence of moist desquamations) were assessed at the end of treatment. The dose distribution in the skin (5mm strip from the patient outline) and in the CTV was evaluated and correlated to the CTCAE scores and the occurrence of moist desquamation.Results42.4% of the patients developed grade I, 55.7% grade II and 2% grade III skin toxicities. Moist desquamation was observed in 59 cases (23.1%). Dose distribution within the CTV and skin was homogenous with only small areas receiving 107% of the prescribed dose (median: 0.7cm(3)) in the CTV and 105% (median 0.5cm(3)) in the skin. On univariate analysis breast size as well as V107%(CTV), V105%(skin) and V80%(skin) correlated significantly (p<0.05) with the incidence of skin toxicity. On multivariate analysis only V80%(skin) was confirmed as independent risk factor.ConclusionModern tangential multi-field 3D-CRT allows a homogeneous dose distribution with similar skin toxicity as compared to studies performing IMRT. Dose distribution within the skin (V80%) might have a relevant impact on the severity of skin toxicity and the occurrence of moist desquamation.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Schlagwörter
3d-crt ; Breast Cancer ; Prognostic Factors ; Radiodermatitis ; Skin; Intensity-modulated Radiotherapy; Acute Skin Toxicity; Radiation-therapy; Dermatitis
Keywords plus
Sprache
englisch
Veröffentlichungsjahr
2018
Prepublished im Jahr
HGF-Berichtsjahr
2018
ISSN (print) / ISBN
1748-717X
e-ISSN
1748-717X
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Quellenangaben
Band: 13,
Heft: 1,
Seiten: ,
Artikelnummer: 218
Supplement: ,
Reihe
Verlag
BioMed Central
Verlagsort
Campus, 4 Crinan St, London N1 9xw, England
Tag d. mündl. Prüfung
0000-00-00
Betreuer
Gutachter
Prüfer
Topic
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Begutachtungsstatus
Peer reviewed
POF Topic(s)
30203 - Molecular Targets and Therapies
Forschungsfeld(er)
Radiation Sciences
PSP-Element(e)
G-501300-001
Förderungen
Copyright
Erfassungsdatum
2018-12-05