PuSH - Publikationsserver des Helmholtz Zentrums München

Schmidt, C.* ; Woda, C.

Quartz thermoluminescence spectra in the high-dose range.

Phys. Chem. Miner. 46, 861-875 (2019)
Postprint DOI
Open Access Green
The red thermoluminescence (RTL) emission of quartz is associated with advantageous features such as high saturation dose and good reproducibility. Previous studies, however, noted inexplicable RTL glow curve shapes with new peaks at large doses (kGy range). Here we present TL spectra of two granitic quartz samples over the additive gamma-dose range 0.1-47.9 kGy. While for doses between 0.4 and 1 kGy the TL spectra are dominated by the red emission at 1.95 eV (630 nm), a blue emission at 2.67 eV (465 nm) becomes prominent for higher doses. For one sample, this blue component completely dominates the spectrum for doses > 12.2 kGy with intensity maxima around 200 degrees C and > 350 degrees C (heating rate 2 K s(-1)). The other sample still contains well resolvable red and blue emissions at the largest dose with similar TL peak positions. Signal saturation for the blue emission in the glow curve range 260-300 degrees C is not yet reached following an additive gamma-dose of 47.9 kGy, whereas the red emission generally shows a more subdued signal response for doses > 5-12 kGy. These findings agree qualitatively with additional monochromatic blue and red TL measurements on the same samples. The evolution of supplementary radiofluorescence spectra over the entire gamma-dose range is more complex, but suggests that the sensitisation of the blue wavelength region occurs during heating and not during irradiation and through creation of electron traps rather than recombination centres (most likely [AlO4](0) sites). The sharp sensitivity increase at 1 kGy might likewise be related to alkali ion redistribution and/or the removal of non-radiative competitive recombination pathways. While the blue emission still requires thorough investigation, care should be taken when recording RTL using optical filters since significant portions of the registered TL could originate from the blue component entering the RTL transmission window. In practical terms, the dose-dependent change in relative intensities of blue and red TL emissions might help in detecting exposure to high doses.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Korrespondenzautor
Schlagwörter Luminescence ; Radiofluorescence ; Red Thermoluminescence ; Gamma-dose ; Sensitivity Change ; Recombination Centre; Optically-stimulated Luminescence; Red Tl; Thermo-luminescence; Landscape Evolution; Emission-spectra; Natural Quartz; Dependence; Thermochronometry; Radioluminescence; Relevant
ISSN (print) / ISBN 0342-1791
e-ISSN 0342-1791
Quellenangaben Band: 46, Heft: 9, Seiten: 861-875 Artikelnummer: , Supplement: ,
Verlag Springer
Verlagsort Berlin ; Heidelberg [u.a.]
Nichtpatentliteratur Publikationen
Begutachtungsstatus Peer reviewed