PuSH - Publikationsserver des Helmholtz Zentrums München

Thompson, K.* ; Adams, K.J.* ; Adamski, J. ; Asad, Y.* ; Borts, D.* ; Bowden, J.A.* ; Byram, G.* ; Gang, V.* ; Dunn, W.B.* ; Fernández, F.* ; Fiehn, O.* ; Gaul, D.A.* ; Hühmer, A.F.* ; Kalli, A.* ; Koal, T.* ; Koeniger, S.* ; Mandal, R.* ; Meier, F.* ; Naser, F.J.* ; O'Neil, D.* ; Pal, A.* ; Patti, G.J.* ; Pham-Tuan, H.* ; Prehn, C. ; Raynaud, F.I.* ; Shen, T.* ; Southam, A.D.* ; St John-Williams, L.* ; Sulek, K.* ; Vasilopoulou, C.G.* ; Viant, M.* ; Winder, C.L.* ; Wishart, D.S.* ; Zhang, L.* ; Zheng, J.* ; Moseley, M.A.*

International ring trial of a high Resolution targeted metabolomics and lipidomics platform for serum and plasma analysis.

Anal. Chem. 91, 14407–14416 (2019)
Forschungsdaten DOI PMC
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
A challenge facing metabolomics in the analysis of large human cohorts is the cross-laboratory comparability of quantitative metabolomics measurements. In this study, 14 laboratories analyzed various blood specimens using a common experimental protocol provided with the Biocrates AbsoluteIDQ p400HR kit, to quantify up to 408 metabolites. The specimens included human plasma and serum from male and female donors, mouse and rat plasma, as well as NIST SRM 1950 reference plasma. The metabolite classes covered range from polar (e.g., amino acids and biogenic amines) to nonpolar (e.g., diacyl-and triacyl-glycerols), and they span 11 common metabolite classes. The manuscript describes a strict system suitability testing (SST) criteria used to evaluate each laboratory's readiness to perform the assay, and provides the SST Skyline documents for public dissemination. The study found approximately 250 metabolites were routinely quantified in the sample types tested, using Orbitrap instruments. Interlaboratory variance for the NIST SRM-1950 has a median of 10% for amino acids, 24% for biogenic amines, 38% for acylcarnitines, 25% for glycerolipids, 23% for glycerophospholipids, 16% for cholesteryl esters, 15% for sphingolipids, and 9% for hexoses. Comparing to consensus values for NIST SRM-1950, nearly 80% of comparable analytes demonstrated bias of <50% from the reference value. The findings of this study result in recommendations of best practices for system suitability, quality control, and calibration. We demonstrate that with appropriate controls, high-resolution metabolomics can provide accurate results with good precision across laboratories, and the p400HR therefore is a reliable approach for generating consistent and comparable metabolomics data.
Impact Factor
Scopus SNIP
Scopus
Cited By
Altmetric
6.350
1.486
41
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Sprache englisch
Veröffentlichungsjahr 2019
HGF-Berichtsjahr 2019
ISSN (print) / ISBN 0003-2700
e-ISSN 1520-6882
Zeitschrift Analytical Chemistry
Quellenangaben Band: 91, Heft: 22, Seiten: 14407–14416 Artikelnummer: , Supplement: ,
Verlag American Chemical Society (ACS)
Begutachtungsstatus Peer reviewed
Institut(e) Molekulare Endokrinologie und Metabolismus (MEM)
POF Topic(s) 30201 - Metabolic Health
Forschungsfeld(er) Genetics and Epidemiology
PSP-Element(e) G-505600-003
Scopus ID 85074869966
PubMed ID 31638379
Erfassungsdatum 2019-11-14