PuSH - Publikationsserver des Helmholtz Zentrums München

Discher, M.* ; Woda, C. ; Lee, J.* ; Kim, H.* ; Chung, K.* ; Lang, A.*

PTTL characteristics of glass samples from mobile phones.

Radiat. Meas. 132:106261 (2020)
DOI
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
Phototransferred thermoluminescence (PTTL) of mobile phone display glass (category A) is systematically investigated to develop a robust measurement protocol for its emergency dosimeter usage after an incident with ionizing radiation. First, optimal readout parameters were defined by varying preheat temperature and holding time preceding violet exposure (405 nm). Next, the detection window of the PTTL measurement was adjusted to optimize the ratio between radiation-induced (RIS) and non-radiation-induced signals (nRIS) of the PTTL. Finally, the developed protocol determines PTTL after preheating to 400 degrees C and holding for 10 s was tested using the detection window centered at 340 nm. Dosimetric properties such as the PTTL reproducibility and dose response were investigated. PTTL signal stability tests showed that the violet PTTL signal originates from deeper and consequently more thermally stable traps. A signal loss of less than 10% after 10.6 days (254 h) storage was observed. Additionally, TL and PTTL spectra were recorded to investigate the luminescence emissions after beta and gamma irradiation and different UV exposures. PTTL emissions are similar to TL emission. Varying UV energy a qualitative comparison demonstrate that the RIS and nRIS PTTL signal intensities increase significantly with decreasing UV stimulation wavelength. In general, the developed PTTL protocol indicates better signal stability and thus some advantages over other techniques, however, further research is needed to test the potential of a new method for physical retrospective dosimetry.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Korrespondenzautor
Schlagwörter Pttl ; Phototransferred Thermoluminescence ; Pttl Of Display Glass ; Dosimetric Properties ; Pttl Emission Spectra ; Physical Retrospective Dosimetry; Thermoluminescence
ISSN (print) / ISBN 1350-4487
e-ISSN 1879-0925
Quellenangaben Band: 132, Heft: , Seiten: , Artikelnummer: 106261 Supplement: ,
Verlag Elsevier
Verlagsort The Boulevard, Langford Lane, Kidlington, Oxford Ox5 1gb, England
Nichtpatentliteratur Publikationen
Begutachtungsstatus Peer reviewed