In a previous paper, Takamiya et al. calculated (63)Ni production in copper samples exposed to the Hiroshima atomic bomb. More specifically, they used their experimental cross-section values of the (63)Cu(n,p)(63)Ni reaction and compared the result with that of the corresponding calculation in the radiation dosimetry system DS02, which used another set of cross-section values. These results were different, and the following two reasons were found: typographical errors in several energy boundary values in the DS02 report that was also used in the calculation by Takamiya et al. and an inappropriate assumption on the cross-section values of the low neutron energy region in the calculation by Takamiya et al. These two issues are described and amended in the present report.