Chi, J.W.* ; Brady, S.M.* ; Moore, N.R.* ; Schnabel, J.A.*

Fusion of perpendicular anisotropic MRI sequences.

In: (2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, 30 March 2011 - 02 April 2011, Chicago, IL, USA). 2011. 1455-1458 (Proceedings - International Symposium on Biomedical Imaging)
DOI
The quality of magnetic resonance images (MRI) is often limited by anisotropic voxels necessitated by acquisition considerations. Examination of the 3D anatomy and post-processing of such images is challenged by the partial volume effects due to such anisotropic voxels. We propose a method based on the separable wavelet transform to fuse anisotropic clinical images, which are often acquired in perpendicular directions, for example axial, sagittal and coronal, into a single fine-resolution image. We investigate several possible wavelet filters, fusion rules and the number of decomposition levels. Our method shows promising results of restoring features apparently lost due to the partial volume effect.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Konferenzbeitrag
Korrespondenzautor
Schlagwörter Anisotropic Mri ; Image Fusion ; Wavelet Transform
ISSN (print) / ISBN 1945-7928
e-ISSN 1945-8452
Konferenztitel 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro
Konferzenzdatum 30 March 2011 - 02 April 2011
Konferenzort Chicago, IL, USA
Quellenangaben Band: , Heft: , Seiten: 1455-1458 Artikelnummer: , Supplement: ,