Murphy, K.* ; Van Ginneken, B.* ; Reinhardt, J.M.* ; Kabus, S.* ; Ding, K.* ; Deng, X.* ; Cao, K.* ; Du, K.* ; Christensen, G.E.* ; Garcia, V.* ; Vercauteren, T.* ; Ayache, N.* ; Commowick, O.* ; Malandain, G.* ; Glocker, B.* ; Paragios, N.* ; Navab, N.* ; Gorbunova, V.* ; Sporring, J.* ; De Bruijne, M.* ; Han, X.* ; Heinrich, M.P.* ; Schnabel, J.A.* ; Jenkinson, M.* ; Lorenz, C.A.* ; Modat, M.* ; McClelland, J.R.* ; Ourselin, S.* ; Muenzing, S.E.A.* ; Viergever, M.A.* ; De Nigris, D.* ; Collins, D.L.* ; Arbel, T.* ; Peroni, M.* ; Li, R.* ; Sharp, G.C.* ; Schmidt-Richberg, A.* ; Ehrhardt, J.* ; Werner, R.* ; Smeets, D.* ; Loeckx, D.* ; Song, G.* ; Tustison, N.* ; Avants, B.* ; Gee, J.C.* ; Staring, M.* ; Klein, S.* ; Stoel, B.C.* ; Urschler, M.* ; Werlberger, M.* ; Vandemeulebroucke, J.* ; Rit, S.* ; Sarrut, D.* ; Pluim, J.P.W.*
Evaluation of registration methods on thoracic CT: The EMPIRE10 challenge.
IEEE Trans. Med. Imaging 30, 1901-1920 (2011)
DOI
Open Access Green möglich sobald Postprint bei der ZB eingereicht worden ist.
EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intrapatient thoracic CT image pairs. Evaluation of nonrigid registration techniques is a nontrivial task. This is compounded by the fact that researchers typically test only on their own data, which varies widely. For this reason, reliable assessment and comparison of different registration algorithms has been virtually impossible in the past. In this work we present the results of the launch phase of EMPIRE10, which comprised the comprehensive evaluation and comparison of 20 individual algorithms from leading academic and industrial research groups. All algorithms are applied to the same set of 30 thoracic CT pairs. Algorithm settings and parameters are chosen by researchers expert in the configuration of their own method and the evaluation is independent, using the same criteria for all participants. All results are published on the EMPIRE10 website (http://empire10.isi.uu.nl). The challenge remains ongoing and open to new participants. Full results from 24 algorithms have been published at the time of writing. This paper details the organization of the challenge, the data and evaluation methods and the outcome of the initial launch with 20 algorithms. The gain in knowledge and future work are discussed. © 2011 IEEE.
Altmetric
Weitere Metriken?
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Korrespondenzautor
Schlagwörter
Chest ; Computed Tomography ; Evaluation ; Registration
Keywords plus
ISSN (print) / ISBN
0278-0062
e-ISSN
1558-254X
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Quellenangaben
Band: 30,
Heft: 11,
Seiten: 1901-1920
Artikelnummer: ,
Supplement: ,
Reihe
Verlag
Institute of Electrical and Electronics Engineers (IEEE)
Verlagsort
New York, NY [u.a.]
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Begutachtungsstatus
Peer reviewed
Institut(e)
Institute for Machine Learning in Biomed Imaging (IML)
Förderungen
Copyright