Tanner, C.* ; Schnabel, J.A.* ; Hill, D.L.G.* ; Hawkes, D.J.* ; Leach, M.O.* ; Hose, D.R.*
Factors influencing the accuracy of biomechanical breast models.
Med. Phys.
33
, 1758-1769 (2006)
DOI
Open Access Green
möglich sobald Postprint bei der ZB eingereicht worden ist.
Abstract
Metriken
Zusatzinfos
Recently it has been suggested that finite element methods could be used to predict breast deformations in a number of applications, including comparison of multimodality images, validation of image registration and image guided interventions. Unfortunately knowledge of the mechanical properties of breast tissues is limited. This study evaluated the accuracy with which biomechanical breast models based on finite element methods can predict the displacements of tissue within the breast in the practical clinical situation where the boundaries of the organ might be known reasonably accurately but there is some uncertainty on the mechanical properties of the tissue. For two datasets, we investigate the influence of tissue elasticity values, Poisson's ratios, boundary conditions, finite element solvers and mesh resolutions. Magnetic resonance images were acquired before and after compressing each volunteer's breast by about 20%. Surface displacement boundary conditions were derived from a three-dimensional nonrigid image registration. Six linear and three nonlinear elastic material models with and without skin were tested. These were compared to hyperelastic models. The accuracy of the models was evaluated by assessing the ability of the model to predict the location of 12 corresponding anatomical landmarks. The accuracy was most sensitive to the Poisson's ratio and the boundary condition. Best results were achieved for accurate boundary conditions, appropriate Poisson's ratios and models where fibroglandular tissue was at most four times stiffer than fatty tissue. These configurations reduced the mean (maximum) distance of the landmarks from 6.6 mm (12.4 mm) to 2.1 mm (3.4 mm) averaged over all experiments. © 2006 American Association of Physicists in Medicine.
Altmetric
Weitere Metriken?
[➜Einloggen]
Tags
Anmerkungen
Besondere Publikation
Zusatzinfos bearbeiten
[➜Einloggen]
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Korrespondenzautor
Schlagwörter
Breast Imaging ; Deformation ; Finite Element Analysis ; Imaged Guided Interventions
Keywords plus
ISSN (print) / ISBN
0094-2405
e-ISSN
1522-8541
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Zeitschrift
Medical Physics
Quellenangaben
Band: 33,
Heft: 6,
Seiten: 1758-1769
Artikelnummer: ,
Supplement: ,
Reihe
Verlag
American Institute of Physics (AIP)
Verlagsort
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Veröffentlichungsnummer
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Nichtpatentliteratur
Publikationen
Begutachtungsstatus
Peer reviewed
Institut(e)
Institute for Machine Learning in Biomed Imaging (IML)
Förderungen
Copyright