PuSH - Publikationsserver des Helmholtz Zentrums München

Schwendner, M.* ; Ille, S.* ; Kirschke, J.S.* ; Bernhardt, D. ; Combs, S.E. ; Meyer, B.* ; Krieg, S.M.*

Clinical evaluation of vertebral body replacement of carbon fiber-reinforced polyetheretherketone in patients with tumor manifestation of the thoracic and lumbar spine.

Acta Neurochir. 165, 897-904 (2023)
Verlagsversion DOI PMC
Open Access Gold (Paid Option)
Creative Commons Lizenzvertrag
PURPOSE: Radiolucent anterior and posterior implants by carbon fiber-reinforced polyetheretherketone (CFR PEEK) aim to improve treatment of primary and secondary tumors of the spine during the last years. The aim of this study was to evaluate clinical and radiological outcomes after dorsoventral instrumentation using a CFR PEEK implant in a cohort of patients representing clinical reality. METHODS: A total of 25 patients with tumor manifestation of the thoracic and lumbar spine underwent vertebral body replacement (VBR) using an expandable CFR PEEK implant between January 2021 and January 2022. Patient outcome, complications, and radiographic follow-up were analyzed. RESULTS: A consecutive series aged 65.8 ± 14.7 (27.6-91.2) years were treated at 37 vertebrae of tumor manifestation, including two cases (8.0%) of primary tumor as well as 23 cases (92.0%) of spinal metastases. Overall, 26 cages covering a median of 1 level (1-4) were implanted. Duration of surgery was 134 ± 104 (65-576) min, with a blood loss of 792 ± 785 (100-4000) ml. No intraoperative cage revision was required. Surgical complications were reported in three (12.0%) cases including hemothorax in two cases (one intraoperative, one postoperative) and atrophic wound healing disorder in one case. In two cases (8.0%), revision surgery was performed (fracture of the adjacent tumorous vertebrae, progressive construct failure regarding cage subsidence). No implant failure was observed. CONCLUSION: VBR using CFR PEEK cages represents a legitimate surgical strategy which opens a variety of improvements-especially in patients in need of postoperative radiotherapy of the spine and MRI-based follow-up examinations.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Korrespondenzautor
Schlagwörter Dorsoventral Instrumentation ; En-bloc Resection ; Polyetheretherketone ; Spinal Metastases ; Vertebral Body Replacement; Metal Artifact Reduction; Metastases; Instrumentation; Disease
ISSN (print) / ISBN 0001-6268
e-ISSN 0942-0940
Zeitschrift Acta neurochirurgica
Quellenangaben Band: 165, Heft: 4, Seiten: 897-904 Artikelnummer: , Supplement: ,
Verlag Springer
Verlagsort Wien [u.a.]
Nichtpatentliteratur Publikationen
Begutachtungsstatus Peer reviewed
Förderungen Nvidia Corp
DePuy Synthes
Spineart Deutschland GmbH
Ulrich Medical
Relievant Medsystems Inc
Icotec AG
Medtronic