Clinical evaluation of vertebral body replacement of carbon fiber-reinforced polyetheretherketone in patients with tumor manifestation of the thoracic and lumbar spine.
Acta Neurochir. 165, 897-904 (2023)
PURPOSE: Radiolucent anterior and posterior implants by carbon fiber-reinforced polyetheretherketone (CFR PEEK) aim to improve treatment of primary and secondary tumors of the spine during the last years. The aim of this study was to evaluate clinical and radiological outcomes after dorsoventral instrumentation using a CFR PEEK implant in a cohort of patients representing clinical reality. METHODS: A total of 25 patients with tumor manifestation of the thoracic and lumbar spine underwent vertebral body replacement (VBR) using an expandable CFR PEEK implant between January 2021 and January 2022. Patient outcome, complications, and radiographic follow-up were analyzed. RESULTS: A consecutive series aged 65.8 ± 14.7 (27.6-91.2) years were treated at 37 vertebrae of tumor manifestation, including two cases (8.0%) of primary tumor as well as 23 cases (92.0%) of spinal metastases. Overall, 26 cages covering a median of 1 level (1-4) were implanted. Duration of surgery was 134 ± 104 (65-576) min, with a blood loss of 792 ± 785 (100-4000) ml. No intraoperative cage revision was required. Surgical complications were reported in three (12.0%) cases including hemothorax in two cases (one intraoperative, one postoperative) and atrophic wound healing disorder in one case. In two cases (8.0%), revision surgery was performed (fracture of the adjacent tumorous vertebrae, progressive construct failure regarding cage subsidence). No implant failure was observed. CONCLUSION: VBR using CFR PEEK cages represents a legitimate surgical strategy which opens a variety of improvements-especially in patients in need of postoperative radiotherapy of the spine and MRI-based follow-up examinations.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Schlagwörter
Dorsoventral Instrumentation ; En-bloc Resection ; Polyetheretherketone ; Spinal Metastases ; Vertebral Body Replacement; Metal Artifact Reduction; Metastases; Instrumentation; Disease
Keywords plus
Sprache
englisch
Veröffentlichungsjahr
2023
Prepublished im Jahr
0
HGF-Berichtsjahr
2023
ISSN (print) / ISBN
0001-6268
e-ISSN
0942-0940
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Quellenangaben
Band: 165,
Heft: 4,
Seiten: 897-904
Artikelnummer: ,
Supplement: ,
Reihe
Verlag
Springer
Verlagsort
Wien [u.a.]
Tag d. mündl. Prüfung
0000-00-00
Betreuer
Gutachter
Prüfer
Topic
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Begutachtungsstatus
Peer reviewed
POF Topic(s)
30203 - Molecular Targets and Therapies
Forschungsfeld(er)
Radiation Sciences
PSP-Element(e)
G-501300-001
Förderungen
Nvidia Corp
DePuy Synthes
Spineart Deutschland GmbH
Ulrich Medical
Relievant Medsystems Inc
Icotec AG
Medtronic
Copyright
Erfassungsdatum
2023-03-01