PuSH - Publikationsserver des Helmholtz Zentrums München

Richer, R.* ; Jorkowitz, J.* ; Stühler, S.* ; Abel, L.* ; Kurz, M.* ; Oesten, M.* ; Griesshammer, S.G.* ; Albrecht, N.C.* ; Küderle, A.* ; Ostgathe, C.* ; Kolpin, A.* ; Steigleder, T.* ; Rohleder, N.* ; Eskofier, B.M.

PEPbench-open, reproducible, and systematic benchmarking of automated pre-ejection period extraction algorithms.

Psychophysiology 62:e70176 (2025)
Verlagsversion Forschungsdaten DOI PMC
Open Access Hybrid
Creative Commons Lizenzvertrag
The pre-ejection period (PEP) is a widely used cardiac parameter in psychophysiology that reflects the duration between the onset of ventricular depolarization and the opening of the aortic valve. PEP is often used as a marker of cardiac sympathetic nervous system (SNS) activity, particularly in within-subject comparisons under similar hemodynamic conditions. While many algorithms for automated PEP extraction from electrocardiography (ECG) and impedance cardiography (ICG) signals (more precisely, its first derivative, dZ/dt) have been proposed in literature, they have not been systematically benchmarked. This lack of standardized algorithm comparisons originates from the absence of open-source algorithms and annotated datasets for evaluating PEP extraction algorithms. To address this issue, we introduce PEPbench, an open-source Python package with different Q-peak and B-point detection algorithms from literature that can be combined to create comprehensive PEP extraction pipelines, and a standardized framework for evaluating PEP extraction algorithms. We use PEPbench to systematically compare 108 different algorithm combinations. All combinations are evaluated on two datasets with manually annotated Q-peaks and B-points, which we make publicly available as the first datasets with reference PEP annotations. Our results show that the algorithms can differ vastly in their performance and that B-point detection algorithms introduce a considerable amount of error. Thus, we suggest that automated PEP extraction algorithms should be used with caution on a beat-to-beat level as their error rates are relatively high. This highlights the need for open and reproducible benchmarking frameworks for PEP extraction algorithms to improve the quality of research findings in the field of psychophysiology. With PEPbench, we aim to take a first step toward this goal and encourage other researchers to engage in the evaluation of PEP extraction algorithms by contributing algorithms, data, and annotations. We hope to establish a community-driven platform, fostering innovation and collaboration in the field of psychophysiology and beyond.
Altmetric
Weitere Metriken?
Zusatzinfos bearbeiten [➜Einloggen]
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter B‐point ; Ecg ; Icg ; Pep ; Q‐peak ; Algorithm Benchmarking ; Dz/dt ; Open Science; Systolic-time Intervals; Pre-ejection Period; Social Stress Test; Beta-adrenergic Influences; Heart-rate-variability; B-point; Impedance; Complex; Impact; Cycle
ISSN (print) / ISBN 0048-5772
e-ISSN 1469-8986
Zeitschrift Psychophysiology
Quellenangaben Band: 62, Heft: 11, Seiten: , Artikelnummer: e70176 Supplement: ,
Verlag Wiley
Verlagsort 111 River St, Hoboken 07030-5774, Nj Usa
Begutachtungsstatus Peer reviewed
Förderungen Deutsche Forschungsgemeinschaft