    Prefocusing inside a linear ion beam guide - a SIMION study.
        
        Int. J. Mass Spectrom. 325, 25-29 (2012)
    
    
    
				A set of 14 stacked ring electrodes was studied by the SIMION ion trajectory simulation program under a pressure of 1 Pa with different applied RF frequencies and RF voltage amplitudes when a classical DC gradient of 38 V/cm is applied. Ion–neutral collision effects were considered by adopting a successful and integrated hard sphere, elastic, ion–neutral collision user program provided by SIMION. Mass dependent ion transmission efficiencies could be obtained. In the classical operation mode of the ion beam guide, a RF frequency of 2 MHz was crucial to obtain very good ion transmission efficiency along a broad mass range. Lower RF frequencies (<1.5 MHz) limited the good transmission efficiencies only to high masses with m/z > 500 amu. SIMION can reproduce expected efficiency curves which show that low m/z ions below 150 amu represent a challenge for such linear ion beam devices even when high RF driving frequency of 2 MHz is applied. The simulations also show that a DC gradient of at least 30 V/cm is crucial to maintain good transmission efficiencies which are in agreement with previously published results. A new operation mode for running the same device is introduced for earlier ion focusing in between the second and fifth ring electrodes, prior to slight beam divergence after the focus point. This required a significant change of the applied DC voltages to alter the shape of the DC gradient curve along the central z axis. The newly identified operation mode allows enhancing the mass dependent ion transmission efficiency in a wide m/z range between 80 and 1000 amu when an RF frequency of 2 MHz is applied to the first ten ring electrodes.
			
			
		Impact Factor
					Scopus SNIP
					Web of Science
Times Cited
					Times Cited
Scopus
Cited By
					
					Cited By
Altmetric
					
				2.549
					0.883
					6
					6
					
					
				Anmerkungen
				
					
						 
						
					
				
			
				
			
				Besondere Publikation
				
					
						 
					
				
			
			
			
				Auf Hompepage verbergern
				
					
						 
					
				
			
			
        Publikationstyp
        Artikel: Journalartikel
    
 
    
        Dokumenttyp
        Wissenschaftlicher Artikel
    
 
     
    
    
        Schlagwörter
        on beam guide; Transmission efficiency; Mass dependency; Operation mode; Ionization Mass-Spectrometry; Funnel Interface; Transmission; Pressure
    
 
     
    
    
        Sprache
        englisch
    
 
    
        Veröffentlichungsjahr
        2012
    
 
     
    
        HGF-Berichtsjahr
        2012
    
 
    
    
        ISSN (print) / ISBN
        1387-3806
    
 
    
        e-ISSN
        1873-2798
    
 
     
     
     
	     
	 
	 
    
        Zeitschrift
        International Journal of Mass Spectrometry
    
 
		
    
        Quellenangaben
        
	    Band: 325,  
	    
	    Seiten: 25-29 
	    
	    
	
    
 
  
         
        
            Verlag
            Elsevier
        
 
         
	
         
         
         
         
         
	
         
         
         
    
         
         
         
         
         
         
         
    
        Begutachtungsstatus
        Peer reviewed
    
 
     
    
        POF Topic(s)
        30202 - Environmental Health
    
 
    
        Forschungsfeld(er)
        Environmental Sciences
    
 
    
        PSP-Element(e)
        G-504800-001
    
 
     
     	
    
    
        WOS ID
        WOS:000309018400005
    
    
        Scopus ID
        84865467581
    
    
        Erfassungsdatum
        2012-08-30