Resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (REMPI-TOFMS) is a powerful technique for the on-line analysis of aromatic compounds with unique features regarding selectivity and sensitivity. Aliphatic compounds, however, are difficult to address by REMPI due to their unfavorable photo ionization properties. This paper describes the proof of concept for an on-line derivatization approach for converting nonaromatic target analytes into specific, photoionizable aromatic derivatives that are readily detectable by REMPI-TOFMS. A multichannel silicone trap or poly(dimethylsiloxane) (PDMS) open tubular capillary was used as a reaction medium for the derivatization of volatile alkyl aldehydes and alkylamines with aromatic "photoionization labels"and to concentrate the resulting aromatic derivatives. The aldehydes formaldehyde, acetaldehyde, acrolein, and crotonal, which when underivatized are poorly detectable by REMPI, were converted into their easily photoionizable phenylhydrazone derivatives by the on-line reaction with phenylhydrazine as reagent. Similarly, the methyl-, ethyl-, propyl-, and butylamines were converted into their REMPI-ionizable benzaldehyde alkylimine derivatives by the on-line reaction with benzaldehyde as reagent. The derivatives were thermally desorbed from the PDMS matrix and transferred into the REMPI-TOFMS for detection. The REMPI-TOFMS detection limits obtained for acetaldehyde; acrolein; crotonal; and methyl-, ethyl-, propyl-, and butylamine using this photo ionization labeling method were in the sub-parts-per-million range and, thus, readily below the permissible exposure limits set by OSHA.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
5.450
0.000
9
8
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter on-line derivatization; time-of-flight mass spectrometry; amines; aldehydes; photo ionization labels; REMPI; REMPI-TOFMS
Sprache englisch
Veröffentlichungsjahr 2005
HGF-Berichtsjahr 0
ISSN (print) / ISBN 0003-2700
e-ISSN 1520-6882
Zeitschrift Analytical Chemistry
Quellenangaben Band: 77, Heft: 1, Seiten: 1-10 Artikelnummer: , Supplement: ,
Verlag American Chemical Society (ACS)
Begutachtungsstatus Peer reviewed
Institut(e) Institute of Ecological Chemistry (IOEC)
PSP-Element(e) G-505100-002
Erfassungsdatum 2005-02-21