möglich sobald bei der ZB eingereicht worden ist.
The ICRP/ICRU adult reference computational phantoms.
Vortrag: MCNEG Monte Carlo User Group Meeting, 30-31 March 2009, Oxford,UK. (2009)
Computational models of the human body have been used together with radiation transport codes for the evaluation of organ dose conversion coefficients in occupational, medical and environmental radiation protection. During the last two decades, the mathematical MIRD-type body models were replaced by voxel models that are derived mostly from medical image data of real persons. Among other laboratories, the Helmholtz Zentrum München – German Research Center for Environmental Health (i.e., the former GSF – National Research Center for Environment and Health) developed 12 voxel models of individuals of different stature and ages: 2 pediatric ones, 4 male and 6 female adult models. It was shown that the simplified schematic organ shapes of the MIRD-type phantoms influence the resulting dose coefficients, which may deviate systematically from those calculated for voxel models in some cases.
Hence, the International Commission on Radiological Protection (ICRP) and the International Commission of Radiation Units and Measurements (ICRU) decided to use voxel models for the update of organ dose conversion coefficients, following the recent revision of the ICRP Recommendations. According to the ICRP, these voxel models should be representative of the adult Reference Male and Reference Female with respect to their external dimensions and their organ masses.
To meet these requirements, at the Helmholtz Zentrum München two voxel adult reference models of a male and a female have been developed upon request of and in collaboration with the ICRP, based on the voxel models of two individuals whose body height and weight resembled the reference values. Approximately 140 organs and tissues were segmented, including also objects that were not previously contained in the MIRD-type phantoms, such as the main blood vessels, cartilage, muscles, and lymphatic nodes. The external dimensions and nearly all organ masses of both models were adjusted to the ICRP reference values. A detailed description of the reference computational phantoms is provided by the ICRP (ICRP Publication 108: Adult reference computational phantoms (in press)). The construction process and the resulting computational phantoms will be presented.
Weitere Metriken?
Zusatzinfos bearbeiten
[➜Einloggen]
Publikationstyp
Sonstiges: Vortrag
Konferenztitel
MCNEG Monte Carlo User Group Meeting
Konferzenzdatum
30-31 March 2009
Konferenzort
Oxford,UK
Institut(e)
Institute of Radiation Protection (ISS)