A fully automatic reference deconvolution strategy to increase the accuracy of in vivo lipid signal quantification.

Magn. Reson. Med. 75, 1391-1401 (2016)
Postprint DOI
Open Access Green
Purpose: Lipid signals measured by H-1 MR spectroscopy cannot be adequately quantified by common fitting routines like VARPRO or AMARES, if lipid spectra are distorted by irregular spatial and temporal inhomogeneities of the static magnetic field during readout. A fully automatic reference deconvolution algorithm is presented that eliminates these distortions before application of fitting routines. Methods: The measured signal of the dominant methyl resonance is isolated with aid of a spectral estimator (estimation of parameters via rotational invariance techniques) and used as reference signal for estimation of distortions. A Wiener filter is applied to deconvolve those distortions in the lipid spectrum. Performance of the algorithm is assessed for different bandwidths and shapes of distortions, using artificially distorted as well as measured data. Results: Application of the fully automatic reference deconvolution algorithm on simulated spectra yields a distinct increase in quantification accuracy. Deconvolved in vivo spectra of subcutaneous fat indicate reduced spectral overlap after application of the proposed strategy. Conclusion: The proposed method is helpful for in vivo magnetic resonance spectroscopy of adipose tissue to correct for effects of field inhomogeneities within the voxel and for inevitable eddy current effects. Quantification accuracy is improved by eliminating distortions before application of fitting routines.
Impact Factor
Scopus SNIP
Altmetric
3.782
1.427
Tags
Anmerkungen
Besondere Publikation
Auf Hompepage verbergern

Zusatzinfos bearbeiten
Eigene Tags bearbeiten
Privat
Eigene Anmerkung bearbeiten
Privat
Auf Publikationslisten für
Homepage nicht anzeigen
Als besondere Publikation
markieren
Publikationstyp Artikel: Journalartikel
Dokumenttyp Wissenschaftlicher Artikel
Schlagwörter Spectral Overlap ; Reference Deconvolution ; Wiener Filter ; Estimation Of Parameters Via Rotational Invariance Techniques Algorithm; Adipose-tissue; Resonance-spectroscopy; Fat; Compartments; Spectra; Invivo; Volume; Mri
Sprache englisch
Veröffentlichungsjahr 2016
HGF-Berichtsjahr 2016
ISSN (print) / ISBN 0740-3194
e-ISSN 1522-2594
Quellenangaben Band: 75, Heft: 4, Seiten: 1391-1401 Artikelnummer: , Supplement: ,
Verlag Wiley
Verlagsort Hoboken
Begutachtungsstatus Peer reviewed
POF Topic(s) 90000 - German Center for Diabetes Research
Forschungsfeld(er) Helmholtz Diabetes Center
PSP-Element(e) G-502400-002
Erfassungsdatum 2016-05-13