Rationale Fast and sensitive detection of aromatic hydrocarbons (AHs) in water is of high importance because of their significant impact on human health and the environment. For this, resonance-enhanced multiphoton ionization (REMPI) coupled to trap-and-release membrane-introduction mass spectrometry (T&R-MIMS) offers the possibility of sensitive on-line water analysis with a time resolution of minutes. Methods REMPI is a versatile tool for sensitive gas-phase analysis, in which AHs are selectively ionized in complex gas mixtures by the subsequent absorption of at least two photons. In T&R-MIMS, selective extraction and enrichment of analytes from water can be achieved using semipermeable membranes. By the subsequent stimulated desorption of enriched compounds, mass spectrometric detection is enabled. Results We present an external T&R inlet for hollow-fiber membranes coupled to REMPI time-of-flight mass spectrometry, which enables direct and sensitive detection of semi-volatile AHs in water. In laboratory experiments, spiked water samples were analyzed. For the investigated compounds, limits of detection (LODs) in the range 1-47 ng/L were determined. The LODs are approximately one order of magnitude lower than in a previously reported continuous membrane-introduction approach using a planar membrane. Further improvement of LOD may be realized by extending the trapping time and by increasing the release temperature. Furthermore, the system was applied to investigate different fuels suspended in water and real water samples. The obtained data are in good agreement with findings of a former study. Conclusions In the framework of the present study, we demonstrate the high potential of the combination of REMPI and T&R-MIMS in the form of a newly developed external hollow-fiber membrane inlet. With the developed system, semi-volatile AHs can be directly detected down to ng/L levels on a minute time scale. The approach thus may pave the way to future ship application in marine sciences, natural resources exploration or pollutant and hazard detection.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Schlagwörter
Semivolatile Organic-compounds; Hydrocarbons Pahs; Polyaromatic Hydrocarbons; Gas-chromatography; Real-time; Ionization; Water; Volatile; Samples; Air
Keywords plus
Sprache
englisch
Veröffentlichungsjahr
2021
Prepublished im Jahr
2020
HGF-Berichtsjahr
2020
ISSN (print) / ISBN
0951-4198
e-ISSN
1097-0231
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Quellenangaben
Band: 35,
Heft: 2,
Seiten: ,
Artikelnummer: e8863
Supplement: ,
Reihe
Verlag
Wiley
Verlagsort
111 River St, Hoboken 07030-5774, Nj Usa
Tag d. mündl. Prüfung
0000-00-00
Betreuer
Gutachter
Prüfer
Topic
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Begutachtungsstatus
Peer reviewed
POF Topic(s)
30202 - Environmental Health
Forschungsfeld(er)
Environmental Sciences
PSP-Element(e)
G-504500-001
Förderungen
Deutsche Forschungsgemeinschaft
Copyright
Erfassungsdatum
2020-06-23