Evaluation of physical retrospective dosimetry methods in a realistic accident scenario: Results of a field test.
Radiat. Meas. 142:106544 (2021)
The radiological incident in Cochabamba (Bolivia, 2002), where members of the general public where exposed to an unshielded Ir-192 radiation source whilst traveling on a bus was replicated here in an attempt to asses and evaluate emerging retrospective dosimetry methodologies using objects of daily life, that are either carried on or close to the human body or can be found in the vicinity of an individual. For this purpose an accidental exposure was simulated under controlled conditions in a secured area and an unshielded radioactive source was placed in the cargo compartment of a bus resembling a Radiological Exposure Device (RED). Water canisters and anthropomorphic phantoms were placed at selected seats on the bus and equipped with personal objects (mobile phones, chip cards) that had reference dosimeters attached to them. At one seat position, additional salt dosimeters and dental ceramics in the phantom were also tested. Two types of 8 h exposures were conducted: one with a source activity similar to the one in Cochabamba (0.65 TBq) and one with a stronger source (1.5 TBq) in order to have more samples with absorbed doses above the detection limit of the different methods. For 43 out of 61 resistor and glass samples from mobile phones, measured doses agreed within error limits with reference doses, but for some materials more research is needed for a more reliable application. In 13 cases outliers with a significant dose over- or underestimation were observed, 10 of these could be identified by combining the results of at least three dose assays. The field test thus evaluated the potential and limitation of retrospective dosimetry using personal objects and demonstrated the importance of using a multi-dosimeter approach to increase robustness of the method.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
Publikationstyp
Artikel: Journalartikel
Dokumenttyp
Wissenschaftlicher Artikel
Typ der Hochschulschrift
Herausgeber
Schlagwörter
Retrospective Dosimetry ; Field Test ; Accident Dosimetry ; Radiological Exposure Device ; Fortuitous Materials
Keywords plus
Sprache
englisch
Veröffentlichungsjahr
2021
Prepublished im Jahr
HGF-Berichtsjahr
2021
ISSN (print) / ISBN
1350-4487
e-ISSN
1879-0925
ISBN
Bandtitel
Konferenztitel
Konferzenzdatum
Konferenzort
Konferenzband
Quellenangaben
Band: 142,
Heft: ,
Seiten: ,
Artikelnummer: 106544
Supplement: ,
Reihe
Verlag
Elsevier
Verlagsort
The Boulevard, Langford Lane, Kidlington, Oxford Ox5 1gb, England
Tag d. mündl. Prüfung
0000-00-00
Betreuer
Gutachter
Prüfer
Topic
Hochschule
Hochschulort
Fakultät
Veröffentlichungsdatum
0000-00-00
Anmeldedatum
0000-00-00
Anmelder/Inhaber
weitere Inhaber
Anmeldeland
Priorität
Begutachtungsstatus
Peer reviewed
POF Topic(s)
30203 - Molecular Targets and Therapies
Forschungsfeld(er)
Radiation Sciences
PSP-Element(e)
G-501391-001
Förderungen
European Community
Copyright
Erfassungsdatum
2021-05-26