PuSH - Publication Server of Helmholtz Zentrum München

Tingberg, A.* ; Herrmann, C. ; Lanhede, B.* ; Almen, A.* ; Sandborg, M.* ; McVey, G.* ; Mattsson, S.* ; Panzer, W. ; Besjakov, J.* ; Mansson, L.G.* ; Kheddache, S.*

Influence of the characteristic curve on the clinical image quality of lumbar spine and chest radiographs.

Br. J. Radiol. 77, 204-215 (2004)
PMC
Open Access Green as soon as Postprint is submitted to ZB.
The "European Guidelines on Quality Criteria for Diagnostic Radiographic Images" do not address the choice of the film characteristic (H&D) curve, which is an important parameter for the description of a radiographic screen-film system. The image contrast of clinical lumbar spine and chest radiographs was altered by digital image processing techniques, simulating images with different H&D curves, both steeper and flatter than the original. The manipulated images were printed on film for evaluation. Seven experienced radiologists evaluated the clinical image quality by analysing the fulfilment of the European Image Criteria (ICS) and by visual grading analysis (VGA) of in total 224 lumbar spine and 360 chest images. A parallel study of the effect of the H&D curve has also been made using a theoretical model. The contrast (DeltaOD) of relevant anatomical details was calculated, using a Monte Carlo simulation-model of the complete imaging system including a 3D voxel phantom of a patient. Correlations between the calculated contrast and the radiologists' assessment by VGA were sought. The results of the radiologists' assessment show that the quality in selected regions of lumbar spine and chest images can be significantly improved by the use of films with a steeper H&D curve compared with the standard latitude film. Significant (p<0.05) correlations were found between the VGA results and the calculations of the contrast of transverse processes and trabecular details in the lumbar spine vertebrae, and with the contrast of blood vessels in the retrocardiac area of the chest.
Impact Factor
Scopus SNIP
Altmetric
1.089
0.000
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords clinical image quality; characteristic curve; screen-film system; visual grading analysis; chest
Language english
Publication Year 2004
HGF-reported in Year 0
ISSN (print) / ISBN 0007-1285
e-ISSN 1748-880X
Quellenangaben Volume: 77, Issue: , Pages: 204-215 Article Number: , Supplement: ,
Publisher British Institute of Radiology N.S
Reviewing status Peer reviewed
POF-Topic(s) 30504 - Mechanisms of Genetic and Environmental Influences on Health and Disease
Research field(s) Radiation Sciences
PSP Element(s) G-501100-008
PubMed ID 15020361
Erfassungsdatum 2004-06-30