Open Access Green as soon as Postprint is submitted to ZB.
Spatial distribution of beta extremity doses in nuclear medicine: A feasibility study with thin α-AI₂O₃:C TLDs.
Phys. Med. 26, 44-48 (2010)
Exposures to the extremities have increased due to new therapeutic protocols involving beta sources. In this study, thermoluminescent dosimeters based on α-Al2O3:C were used to map the dose distribution to the extremities of physicians and paramedical personnel handling beta emitters. The results showed a strong inhomogeneous dose distribution between different phalanxes, fingers and hands of all the investigated subjects, without an indication of systematic trends in the dose patterns. Consequently, conventional dosimetric practices, based on the use of wrist or ring dosimeters, may be not suitable for providing reliable assessments of the inhomogeneous doses received at the fingertip.
Altmetric
Additional Metrics?
Edit extra informations
Login
Publication type
Article: Journal article
Document type
Scientific Article
Keywords
TLD; extremity dosimetry; α-Al2O3:C; Beta radiation
ISSN (print) / ISBN
1120-1797
e-ISSN
1724-191X
Quellenangaben
Volume: 26,
Issue: 1,
Pages: 44-48
Publisher
Elsevier
Non-patent literature
Publications
Reviewing status
Peer reviewed
Institute(s)
Institute of Radiation Protection (ISS)