Open Access Gold as soon as Publ. Version/Full Text is submitted to ZB.
Peak identification for PCDD/Fs in environmental samples at different temperature programs.
Chemosphere 40, 601-608 (2000)
A method has been developed for peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) at different temperature programs. Their retention behaviours are predicted on the basis of an identification database of retention values (A, B) of gas chromatography. By the retention times of 13C labelled 2,3,7,8-substituted PCDD/F internal standards, the retentions of all PCDDs and PCDFs can be calculated. After comparison with the retentions of practical environmental samples, the predicted values have been proved to be very accurate.
Impact Factor
Scopus SNIP
Scopus
Cited By
Cited By
Altmetric
1.255
0.000
1
Annotations
Special Publikation
Hide on homepage
Publication type
Article: Journal article
Document type
Scientific Article
Keywords
PCDD/Fs Gas chromatography Identification Internal standards
Language
english
Publication Year
2000
HGF-reported in Year
0
ISSN (print) / ISBN
0045-6535
e-ISSN
1879-1298
Journal
Chemosphere
Quellenangaben
Volume: 40,
Issue: 6,
Pages: 601-608
Publisher
Elsevier
Publishing Place
Kidlington, Oxford
Reviewing status
Peer reviewed
Institute(s)
Institute of Ecological Chemistry (IOEC)
POF-Topic(s)
Research field(s)
PSP Element(s)
G-505100-006
Erfassungsdatum
2000-12-31