Open Access Green as soon as Postprint is submitted to ZB.
		
    Determination of the calibration factor of polysulphone film UV dosemeters for terrestrial solar radiation.
        
        Radiat. Prot. Dosim. 95, 345-352 (2001)
    
    
    
	    Polysulphone film is used as a personal UV dosemeter in dermatological or epidemiological studies. The relative efficiency of this detector does not exactly match the action spectrum as proposed by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and to which the UV dose and exposure limits refer. Therefore, the calibration of the dosemeter depends on the spetrum. In the present paper the variation of the calibration factor for terrestrial solar UV spectra is analysed on the basis of a two year observation period at a site near Munich. Germany. A detailed error estimation is included. It is shown that the variation of the calibration factor within this class of spectra is the main contribution to the total uncertainty of the dose determination, which can be up to 40%. The shape of the spectrum of terrestrial solar UV radiation is mainly determined by the total ozone column and the solar elevation angle. It is shown how the calibration depends on these two parameters and how this additional information can help to reduce the measurement error to a residual uncertainty of 17%. Exposure studies of terrestrial solar UV radiation using polysulphone film as a dosemeter would gain in accuracy if total ozone column values at the study's site could be measured or taken from satellite or weather service data. The interpretation of the magnitude of the dose uncertainty depends on the further use of these data.
	
	
      Impact Factor
		Scopus SNIP
		Web of Science
Times Cited
		
		Times Cited
Altmetric
		
	    0.000
		0.000
		11
		
		
	    Annotations
	    
		
		     
		    
		
	    
	
		
	
	    Special Publikation
	    
		
		     
		
	    
	
	
	
	    Hide on homepage
	    
		
		     
		
	    
	
	
        Publication type
        Article: Journal article
    
 
    
        Document type
        Scientific Article
    
 
     
    
    
        Keywords
        ULTRAVIOLET; OUTDOOR
    
 
     
    
    
        Language
        english
    
 
    
        Publication Year
        2001
    
 
     
    
        HGF-reported in Year
        0
    
 
    
    
        ISSN (print) / ISBN
        0144-8420
    
 
    
        e-ISSN
        1742-3406
    
 
    
     
     
	     
	 
	 
    
        Journal
        Radiation Protection Dosimetry
    
 
	
    
        Quellenangaben
        
	    Volume: 95,  
	    Issue: 4,  
	    Pages: 345-352 
	    
	    
	
    
 
    
         
        
            Publisher
            Oxford University Press
        
 
        
            Publishing Place
            Oxford
        
 
	
         
         
         
         
         
	
         
         
         
    
         
         
         
         
         
         
         
    
        Reviewing status
        Peer reviewed
    
 
    
        Institute(s)
        Research Unit Environmental Simulation (EUS)
    
 
     
     
     
     
     	
    
        PubMed ID
        11707033
    
    
        WOS ID
        WOS:000171944300007
    
    
        Erfassungsdatum
        2001-12-31