Romm, H.* ; Barnard, S.* ; Boulay-Greene, H.* ; de Amicis, A.* ; de Sanctis, S.* ; Franco, M.* ; Herodin, F.* ; Jones, A.* ; Kulka, U.* ; Lista, F.* ; Martigne, P.* ; Moquet, J.* ; Oestreicher, U.* ; Rothkamm, K.* ; Thierens, H.* ; Valente, M.* ; Vandersickel, V.* ; Vral, A.* ; Braselmann, H. ; Meineke, V.* ; Abend, M.* ; Beinke, C.*

Laboratory intercomparison of the cytokinesis-block micronucleus assay.

Radiat. Res. 180, 120-128 (2013)
Publ. Version/Full Text DOI PMC
Open Access Green as soon as Postprint is submitted to ZB.
The focus of the study is an intercomparison of laboratories' dose-assessment performances using the cytokinesis-block micronucleus (CBMN) assay as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25-5 Gy) as well as blind samples (0.1-6.4 Gy) were sent to the participants. The CBMN assay was performed according to protocols individually established and varying among participating laboratories. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 4 days after sample arrival. The CBMN dose estimates were reported with high accuracy (MAD values of 0.20-0.50 Gy at doses below 6.4 Gy for both manual and automated scoring procedures), but showed a limitation of the assay at the dose point of 6.4 Gy, which resulted in a clear dose underestimation in all cases. The MAD values (without 6.4 Gy) differed significantly (P = 0.03) between manual (0.25 Gy, SEM = 0.06, n = 4) or automated scoring procedures (0.37 Gy, SEM = 0.08, n = 5), but lowest MAD were equal (0.2 Gy) for both scoring procedures. Likewise, both scoring procedures led to the same allocation of dose estimates to triage categories of clinical significance (about 83% accuracy and up to 100% specificity).
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
2.698
1.326
30
35
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords Peripheral-blood Lymphocytes; Radiation Biodosimetry; Biological Dosimetry; Ionizing-radiation; Image-analysis; Sensitivity; Accidents; Exposure; Network; Emergencies
Language english
Publication Year 2013
HGF-reported in Year 2013
ISSN (print) / ISBN 0033-7587
e-ISSN 1938-5404
Quellenangaben Volume: 180, Issue: 2, Pages: 120-128 Article Number: , Supplement: ,
Publisher Radiation Research Society
Publishing Place Lawrence
Reviewing status Peer reviewed
POF-Topic(s) 30203 - Molecular Targets and Therapies
Research field(s) Radiation Sciences
PSP Element(s) G-501000-001
PubMed ID 23862731
Scopus ID 84882283493
Erfassungsdatum 2013-09-23