Rothkamm, K.* ; Beinke, C.* ; Romm, H.* ; Badie, C.* ; Balagurunathan, Y.* ; Barnard, S.* ; Bernard, N.* ; Boulay-Greene, H.* ; Brengues, M.* ; de Amicis, A.* ; de Sanctis, S.* ; Greither, R.* ; Herodin, F.* ; Jones, A.* ; Kabacik, S.* ; Knie, T.* ; Kulka, U.* ; Lista, F.* ; Martigne, P.* ; Missel, A.* ; Moquet, J.* ; Oestreicher, U.* ; Peinnequin, A.* ; Poyot, T.* ; Roessler, U.* ; Scherthan, H.* ; Terbrueggen, B.* ; Thierens, H.* ; Valente, M.* ; Vral, A.* ; Zenhausern, F.* ; Meineke, V.* ; Braselmann, H. ; Abend, M.*
Comparison of established and emerging biodosimetry assays.
Radiat. Res. 180, 111-119 (2013)
Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
Publication type
Article: Journal article
Document type
Scientific Article
Thesis type
Editors
Keywords
Biological Dosimetry; Radiation-exposure; Triage; Network; Emergency; Dna; Casualties; Accidents; Biomarker; Damage
Keywords plus
Language
english
Publication Year
2013
Prepublished in Year
HGF-reported in Year
2013
ISSN (print) / ISBN
0033-7587
e-ISSN
1938-5404
ISBN
Book Volume Title
Conference Title
Conference Date
Conference Location
Proceedings Title
Quellenangaben
Volume: 180,
Issue: 2,
Pages: 111-119
Article Number: ,
Supplement: ,
Series
Publisher
Radiation Research Society
Publishing Place
Lawrence
Day of Oral Examination
0000-00-00
Advisor
Referee
Examiner
Topic
University
University place
Faculty
Publication date
0000-00-00
Application date
0000-00-00
Patent owner
Further owners
Application country
Patent priority
Reviewing status
Peer reviewed
POF-Topic(s)
30203 - Molecular Targets and Therapies
Research field(s)
Radiation Sciences
PSP Element(s)
G-501000-001
Grants
Copyright
Erfassungsdatum
2013-09-23