PuSH - Publication Server of Helmholtz Zentrum München

Sensitivity improvement in hydrophilic interaction chromatography negative mode electrospray ionization mass spectrometry using 2-(2-methoxyethoxy)ethanol as a post-column modifier for non-targeted metabolomics.

J. Chromatogr. A 1361, 209-216 (2014)
Publ. Version/Full Text DOI PMC
Closed
Open Access Green as soon as Postprint is submitted to ZB.
The application of ammonia acetate buffered liquid chromatography (LC) eluents is known to concomitantly lead to ion suppression when electrospray ionization mass spectrometry (ESI-MS) detection is used. In negative ESI mode, post column infusion of 2-(2-methoxyethoxy)ethanol (2-MEE) was shown in the literature to help to compensate this adverse effect occurring in reversed phase liquid chromatography mass spectrometry (RP-LC-MS) analyses. Here a setup of direct infusion and hydrophilic interaction chromatography (HILIC) post-column infusion experiments was established in order to investigate systematically the beneficial effects of 2-MEE. We demonstrate that, 2-MEE can help to improve ESI-MS sensitivity in HILIC too and reveal analyte structure specific behaviors. Our study indicates that 2-MEE especially improves ESI response for small and polar molecules. The ESI response of stable isotope labeled amino acids spiked into biological matrices increases up to 50-fold (i.e. D5-l-glutamic acid) when post column infusion of 2-MEE is applied. A non-targeted analysis of a pooled urine sample via HILIC-ESI-QTOF-MS supports this hypothesis. In direct infusion, the combined application of an ammonia acetate buffered solution together with 2-MEE results in an improved ESI response compared to a non-buffered solution. We observed up to 60-fold increased ESI response of l-lysine. We propose this effect is putatively caused by the formation of smaller ESI droplets and stripping of positive charge from ESI droplets due to evaporation of acetic acid anions. In summary, post-column infusion of 2-MEE especially enhances ESI response of small and polar molecules. Therefore it can be regarded as a valuable add-on in targeted or non-targeted metabolomic HILIC-MS studies since this method sets a focus on this molecule category.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
4.258
1.614
8
8
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords 2-(2-methoxyethoxy)ethanol ; Dopant ; Hydrophilic Interaction Chromatography ; Metabolomics ; Time Of Flight Mass Spectrometry ; Ultra-high Pressure Liquid Chromatography; Liquid-chromatography; Hmdb; Suppression; Droplets; Database; Phases
Language english
Publication Year 2014
HGF-reported in Year 2014
ISSN (print) / ISBN 0021-9673
e-ISSN 1873-3778
Quellenangaben Volume: 1361, Issue: , Pages: 209-216 Article Number: , Supplement: ,
Publisher Elsevier
Publishing Place Amsterdam
Reviewing status Peer reviewed
POF-Topic(s) 30202 - Environmental Health
90000 - German Center for Diabetes Research
Research field(s) Environmental Sciences
Helmholtz Diabetes Center
PSP Element(s) G-504800-001
G-502400-001
PubMed ID 25160955
Scopus ID 84919701688
Scopus ID 84906072536
Erfassungsdatum 2014-08-27