Open Access Green as soon as Postprint is submitted to ZB.
Variation of organ doses in paediatric radiology due to patient diameter, calculated with phantoms of varying voxel size.
Radiat. Prot. Dosim. 49, 353-356 (1993)
The voxel type phantoms BABY and CHILD are used to quantify the dependence of organ dose per exit dose conversion factors on patient diameter in diagnostic paediatric radiology by variation of the voxel size in the relevant dimension. The results of Monte Carlo simulations of the five most frequent examinations, i.e. skull AP, thorax AP and PA, abdomen AP and pelvis AP, are presented for both phantoms. The organ doses increase very differently with increasing patient diameter, depending on the phantom, the examination, the radiation quality and the relative position and percentage of the organ in the beam. Using these results, phantom and examination specific organ dose scaling factors from 'standard patients' to patients with different diameters can be obtained.
Altmetric
Additional Metrics?
Edit extra informations
Login
Publication type
Article: Journal article
Document type
Scientific Article
ISSN (print) / ISBN
0144-8420
e-ISSN
1742-3406
Journal
Radiation Protection Dosimetry
Quellenangaben
Volume: 49,
Issue: 1-3,
Pages: 353-356
Publisher
Oxford University Press
Publishing Place
Oxford
Reviewing status
Peer reviewed
Institute(s)
Institute of Radiation Protection (ISS)