Open Access Green as soon as Postprint is submitted to ZB.
Organ doses and effective dose equivalent.
Radiat. Prot. Dosim. 12, 101-106 (1985)
For a modified version of the anthropoid MIRD phantom the organ doses and the effective dose equivalent for external neutron irradiation have been calculated in the past by the so called CHORD method. It was anticipated from a few preliminary Monte Carlo Calculations and based upon basic physical considerations that CHORD results may be generally too high in the case of organs positioned on the exit side of radiation, especially for the smaller head and neck part of the phantom. To prove this, extensive calculations have been performed with the Monte Carlo code SAM-CE for a male and a female phatom and the results of both calculations have been intercompared. In addition, organ doses were derived by the CHORD method for gamma irradiation, and have been compared with Monte Carlo calculations by other authors. The deviations are discussed with respect to their relevance for the determination of the primary limited quantities and with respect to the economy of the calculations.
Impact Factor
Scopus SNIP
Altmetric
0.000
0.000
Annotations
Special Publikation
Hide on homepage
Publication type
Article: Journal article
Document type
Scientific Article
Language
english
Publication Year
1985
HGF-reported in Year
0
ISSN (print) / ISBN
0144-8420
e-ISSN
1742-3406
Journal
Radiation Protection Dosimetry
Quellenangaben
Volume: 12,
Issue: 2,
Pages: 101-106
Publisher
Oxford University Press
Publishing Place
Oxford
Reviewing status
Peer reviewed
Institute(s)
Institute of Radiation Protection (ISS)
Scopus ID
0022350754
Erfassungsdatum
1985-12-31