PuSH - Publication Server of Helmholtz Zentrum München

Chernobyl fallout size distribution in urban areas.

J. Aerosol Sci. 18, 689-692 (1987)
DOI
Open Access Green as soon as Postprint is submitted to ZB.
The measurement of the radioactive aerosol size distribution was performed using a low pressure cascade impactor (Berner Impactor, Hauke Inc. ) with 9 stages. One impactor (sited in Vienna) had two additional stages in the Aitken particle range. Thin polyethylene foil was used as collection medium on each impactor stage. Gamma spectrometry with high purity Germanium detectors was made of each foil of collected activity. The integrated activity of each set of impactor foils was in good agreement with filter measurements of the airborne activity of the same time period. Study results are discussed.
Altmetric
Additional Metrics?
Edit extra informations Login
Publication type Article: Journal article
Document type Scientific Article
Corresponding Author
ISSN (print) / ISBN 0021-8502
e-ISSN 1879-1964
Quellenangaben Volume: 18, Issue: 6, Pages: 689-692 Article Number: , Supplement: ,
Publisher Elsevier
Non-patent literature Publications
Reviewing status Peer reviewed