as soon as is submitted to ZB.
Tetrahedral-mesh counterparts of ICRP reference computational phantoms.
Vortrag: 12th Congress of the World Federation of Nuclear Medicine and Biology, 20-24 April 2018, Melbourne, Australia. (2018)
Background / Aims: This talk is to introduce the new adult male and female mesh-type reference computational phantoms (MRCPs) recently developed in the International Commission on Radiological Protection (ICRP), generally discussing their advantages over the current voxel-type reference computational phantoms (VRCPs)[1]. Methods: The MRCPs were constructed by converting the VRCPs to a high-quality tetrahedral-mesh format and addressing the limitations of the VRCPs mostly due to their limited voxel resolutions. The MRCPs were implemented in Monte Carlo codes (i.e., Geant4, MCNP6, and PHITS) to investigate computation speed and memory usage. In addition, dose coefficients (DCs) of the MRCPs for some external and internal exposures were calculated and compared with the current reference DCs produced with the VRCPs and supplemental stylized phantoms[2,3]. Furthermore, the MRCPs, using their high deformability over the VRCPs, were transformed to phantoms in different statures or postures, which were then used to calculate DCs for industrial radiography sources near the body. Results: The MRCPs include all the target and source regions needed for effective dose calculations, even micron-scale regions of the respiratory and alimentary tract organs, urinary bladder, skin, and eye lens, completely obviating the need of supplemental stylized phantoms. PHITS, compared to Geant4 and MCNP6, showed the best performance in both computation speed and memory usage for the MRCPs, which are even faster than the VRCPs. The DCs of the MRCPs were found to be very similar to the current reference DCs for penetrating radiations (e.g., photons and neutrons), but more reliable for weakly penetrating radiations (e.g., electrons and ions). The DCs for industrial radiography sources were found to be significantly influenced by different statures, demonstrating the capability of the MRCPs for personalized dosimetry. Conclusion: The MRCPs, as the next generation of ICRP reference computa
Additional Metrics?
Edit extra informations
Login
Publication type
Other: Lecture
Conference Title
12th Congress of the World Federation of Nuclear Medicine and Biology
Conference Date
20-24 April 2018
Conference Location
Melbourne, Australia
Institute(s)
Institute of Radiation Protection (ISS)