PuSH - Publication Server of Helmholtz Zentrum München

Terwisscha van Scheltinga, A.G.* ; van Dam, G.M.* ; Nagengast, W.B.* ; Ntziachristos, V. ; Hollema, H.* ; Herek, J.L.* ; Schröder, C.P.* ; Kosterink, J.G.* ; Lub-de, Hoog, M.N.* ; de Vries, E.G.*

Intraoperative near-infrared fluorescence tumor imaging with vascular endothelial growth factor and human epidermal growth factor receptor 2 targeting antibodies.

J. Nucl. Med. 52, 1778-1785 (2011)
Publ. Version/Full Text DOI PMC
Closed
Open Access Green as soon as Postprint is submitted to ZB.
Fluorescence imaging is currently attracting much interest as a method for intraoperative tumor detection, but most current tracers lack tumor specificity. Therefore, this technique can be further improved by tumor-specific detection. With tumor-targeted antibodies bound to a radioactive label, tumor-specific SPECT or PET is feasible in the clinical setting. The aim of the present study was to apply antibody-based tumor detection to intraoperative optical imaging, using preclinical in vivo mouse models. METHODS: Anti-vascular endothelial growth factor (VEGF) antibody bevacizumab and anti-human epidermal growth factor receptor (HER) 2 antibody trastuzumab were labeled with the near-infrared (NIR) fluorescence dye IRDye 800CW. Tumor uptake of the fluorescent tracers and their (89)Zr-labeled radioactive counterparts for PET was determined in human xenograft-bearing athymic mice during 1 wk after tracer injection, followed by ex vivo biodistribution and pathologic examination. Intraoperative imaging of fluorescent VEGF- or HER2-positive tumor lesions was performed in subcutaneous tumors and in intraperitoneal dissemination tumor models. RESULTS: Tumor-to-background ratios, with fluorescent imaging, were 1.93 ± 0.40 for bevacizumab and 2.92 ± 0.29 for trastuzumab on day 6 after tracer injection. Real-time intraoperative imaging detected tumor lesions at even the submillimeter level in intraperitoneal dissemination tumor models. These results were supported by standard histology, immunohistochemistry, and fluorescence microscopy analyses. CONCLUSION: NIR fluorescence-labeled antibodies targeting VEGF or HER2 can be used for highly specific and sensitive detection of tumor lesions in vivo. These preclinical findings encourage future clinical studies with NIR fluorescence-labeled tumor-specific antibodies for intraoperative-guided surgery in cancer patients.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
7.022
2.345
84
159
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords molecular imaging; Monoclonal antibodies; oncology; intraoperative imaging; near-infrared fluorescence
Language english
Publication Year 2011
HGF-reported in Year 2011
ISSN (print) / ISBN 0161-5505
e-ISSN 1535-5667
Quellenangaben Volume: 52, Issue: 11, Pages: 1778-1785 Article Number: , Supplement: ,
Publisher Society of Nuclear Medicine and Molecular Imaging
Reviewing status Peer reviewed
POF-Topic(s) 30205 - Bioengineering and Digital Health
Research field(s) Enabling and Novel Technologies
PSP Element(s) G-505500-001
PubMed ID 21990576
Erfassungsdatum 2011-11-22