Accurate in situ calibration of the energy bandwidth and the zero-energy offset in SIMS analysis using magnetic sector field instruments.

Int. J. Mass Spectrom. 300, 65-69 (2011)
Postprint DOI
Open Access Green
Instruments used for basic studies in secondary ion mass spectrometry (SIMS) are usually not very well characterized in terms of important experimental parameters like the energy bandwidth and the origin of the energy scale. A proof-of-concept is presented which shows that in magnetic sector field mass spectrometers this kind of information can be obtained rather easily by determining the spectral features of ions generated by primary ion impact on a gas deliberately introduced in the extraction region above the sample. Owing to the negligible kinetic energy of the gas atoms, the measured energy spectrum exhibits a well-defined edge which corresponds to moving the energy bandpass through the gas–solid interface at the target surface. The energy resolution function can be derived as the derivative of the measured data. For high accuracy it is mandatory that the detected ions originate from a volume that is uniformly illuminated by the primary ion beam. The validity of the concept is demonstrated by evaluating recently published literature data. Even though the experiments were performed with a rather large bandwidth, shown to be 30.2 eV, the highly symmetric resolution function allowed the origin of the energy scale to be determined with an accuracy of ±0.2 eV. The potential of the approach needs to be explored in more detail by varying the relevant experimental parameters.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
2.009
0.862
3
4
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords Secondary ion mass spectrometry; Energy bandwidth; Energy offset; Gas-phase ionization
Language english
Publication Year 2011
HGF-reported in Year 2011
ISSN (print) / ISBN 1387-3806
e-ISSN 1873-2798
Quellenangaben Volume: 300, Issue: 1, Pages: 65-69 Article Number: , Supplement: ,
Publisher Elsevier
Reviewing status Peer reviewed
POF-Topic(s) 30504 - Mechanisms of Genetic and Environmental Influences on Health and Disease
Research field(s) Radiation Sciences
PSP Element(s) G-501100-006
Scopus ID 79551689801
Erfassungsdatum 2011-07-07