Feasibility of precise and reliable glucose quantification in human whole blood samples by 1 tesla benchtop NMR.
NMR Biomed.:e4358 (2020)
The standard procedure for blood glucose measurements is enzymatic testing. This method is cheap, but requires small samples of open blood with direct contact to the test medium. In principle, NMR provides non-contact analysis of body fluids, but high-field spectrometers are expensive and cannot be easily utilized under clinical conditions. Low-field NMR systems with permanent magnets are becoming increasingly smaller and more affordable. The studies presented here aim at exploring the capabilities of low-field NMR for measuring glucose concentrations in whole blood. For this purpose, a modern 1 T benchtop NMR spectrometer was used. Challenges arise from broad spectral lines, the glucose peak locations close to the water signal, low SNR and the interference with signals from other blood components. Whole blood as a sample comprises even more boundary conditions: crucial for reliable results are avoiding the separation of plasma and cells by gravitation and reliable reference values. First, the accuracy of glucose levels measured by NMR was tested using aqueous glucose solutions and commercially available bovine plasma. Then, 117 blood samples from oral glucose tolerance testing were measured with minimal preparation by simple pulse-acquire NMR experiments. The analysis itself is the key to achieve high precision, so several approaches were investigated: peak integration, orthogonal projection to latent structure analysis and support vector machine regression. Correlations between results from the NMR spectra and the routine laboratory automated analyzer revealed an RMSE of 7.90 mg/dL for the best model. 91.5% of the model output lies within the limits of the German Medical Association guidelines, which require the glucose measurement to be within 11% of the reference method. It is concluded that spectral quantification of glucose in whole blood samples by high-quality NMR spectrometers operating at 1 T is feasible with sufficient accuracy.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
Publication type
Article: Journal article
Document type
Scientific Article
Thesis type
Editors
Keywords
Applications ; Body ; Diabetes ; Methods And Engineering ; Mrs And Mrsi Methods ; Post-acquisition Processing ; Quantitation ; Spectroscopic Quantitation; Spectroscopy; Plasma; Urine; Serum; Indicator; Level; H-1
Keywords plus
Language
english
Publication Year
2020
Prepublished in Year
HGF-reported in Year
2020
ISSN (print) / ISBN
0952-3480
e-ISSN
1099-1492
ISBN
Book Volume Title
Conference Title
Conference Date
Conference Location
Proceedings Title
Quellenangaben
Volume: ,
Issue: ,
Pages: ,
Article Number: e4358
Supplement: ,
Series
Publisher
Wiley
Publishing Place
111 River St, Hoboken 07030-5774, Nj Usa
Day of Oral Examination
0000-00-00
Advisor
Referee
Examiner
Topic
University
University place
Faculty
Publication date
0000-00-00
Application date
0000-00-00
Patent owner
Further owners
Application country
Patent priority
Reviewing status
Peer reviewed
POF-Topic(s)
90000 - German Center for Diabetes Research
Research field(s)
Helmholtz Diabetes Center
PSP Element(s)
G-502400-001
Grants
Copyright
Erfassungsdatum
2020-07-07