Ma, R.* ; Qiu, R.* ; Wu, Z.* ; Ren, L.* ; Hu, A.* ; Li, W.B. ; Li, J.*
     
    
        
Development of Chinese mesh-type pediatric reference phantoms series and application in dose assessment of Chinese undergoing computed tomography scanning.
    
    
        
    
    
        
        Phys. Med. Biol. 66:195002 (2021)
    
    
    
      
      
	
	    The pediatric patients are in the growing stage with more dividing cells than adults. They are greater sensitive to the radiation dose undergoing computed tomography (CT) scanning. It is necessary and essential to assess the absorbed dose and effective dose to children. Monte Carlo simulation with computational phantoms is one of the most used methods for dose calculation in medical imaging and radiotherapy. Because of the vast change of the pediatric body with age increasing, many research groups developed series pediatric phantoms for various ages. However, most of the existing pediatric reference phantoms were developed based on Caucasian populations, which is not conformable to Chinese pediatric patients. The use of different phantoms can contribute a difference in the dose calculation. To assess the CT dose of Chinese pediatric patients more accurately, we developed the Chinese pediatric reference phantoms series, including the 3-month (CRC3m), 1-year-old (CRC01), 5-year-old (CRC05), 10-year-old (CRC10), 15-year-old male (CRCM15), and female (CRCF15) phantoms. Furthermore, we applied them to dose assessment of patients undergoing CT scanning. The GE LightSpeed 16 CT scanner was constructed and the paper presents the detailed process of phantoms development and the establishment of the CT dose database (with X-ray tube voltages of 120, 100, and 80 kVp, with collimators of 20, 10, and 5 mm width, with filters for head and body), compares our results with other results based on different phantoms, and analyzes the CT dose calculation results. It was found that the difference in phantoms' characteristics, organ masses, and positions had a significant impact on the CT dose calculation results. The maximum difference came up to 463% (gonads dose undergoing chest examinations). The results are helpful for the dose optimization of Chinese pediatric patients undergoing CT scanning. The developed phantoms could be applied in dose estimation of other medical modalities.
	
	
	    
	
       
      
	
	    
		Impact Factor
		Scopus SNIP
		Web of Science
Times Cited
		Scopus
Cited By
		Altmetric
		
	     
	    
	 
       
      
     
    
        Publication type
        Article: Journal article
    
 
    
        Document type
        Scientific Article
    
 
    
        Thesis type
        
    
 
    
        Editors
        
    
    
        Keywords
        Chinese Mesh-type Pediatric Reference Phantoms ; Computed Tomography Scanning ; Monte Carlo Simulation ; Organ Dose; Ct; Adult
    
 
    
        Keywords plus
        
    
 
    
    
        Language
        english
    
 
    
        Publication Year
        2021
    
 
    
        Prepublished in Year
        
    
 
    
        HGF-reported in Year
        2021
    
 
    
    
        ISSN (print) / ISBN
        0031-9155
    
 
    
        e-ISSN
        1361-6560
    
 
    
        ISBN
        
    
    
        Book Volume Title
        
    
 
    
        Conference Title
        
    
 
	
        Conference Date
        
    
     
	
        Conference Location
        
    
 
	
        Proceedings Title
        
    
 
     
	
    
        Quellenangaben
        
	    Volume: 66,  
	    Issue: 19,  
	    Pages: ,  
	    Article Number: 195002 
	    Supplement: ,  
	
    
 
    
        
            Series
            
        
 
        
            Publisher
            Institute of Physics Publishing (IOP)
        
 
        
            Publishing Place
            Bristol
        
 
	
        
            Day of Oral Examination
            0000-00-00
        
 
        
            Advisor
            
        
 
        
            Referee
            
        
 
        
            Examiner
            
        
 
        
            Topic
            
        
 
	
        
            University
            
        
 
        
            University place
            
        
 
        
            Faculty
            
        
 
    
        
            Publication date
            0000-00-00
        
 
         
        
            Application date
            0000-00-00
        
 
        
            Patent owner
            
        
 
        
            Further owners
            
        
 
        
            Application country
            
        
 
        
            Patent priority
            
        
 
    
        Reviewing status
        Peer reviewed
    
 
     
    
        POF-Topic(s)
        30203 - Molecular Targets and Therapies
    
 
    
        Research field(s)
        Radiation Sciences
    
 
    
        PSP Element(s)
        G-501391-001
    
 
    
        Grants
        Tsinghua University Initiative Scientific Research Program
National Natural Science Foundation of China
    
 
    
        Copyright
        
    
 	
    
    
    
    
    
        Erfassungsdatum
        2021-10-04