PuSH - Publication Server of Helmholtz Zentrum München

Yu, Z. ; Kastenmüller, G. ; He, Y. ; Belcredi, P. ; Möller, G. ; Prehn, C. ; Mendes, J. ; Wahl, S. ; Römisch-Margl, W. ; Ceglarek, U.* ; Polonikov, A.* ; Dahmen, N.* ; Prokisch, H. ; Xie, L.* ; Li, Y.* ; Wichmann, H.-E. ; Peters, A. ; Kronenberg, F.* ; Suhre, K. ; Adamski, J. ; Illig, T. ; Wang-Sattler, R.

Differences between human plasma and serum metabolite profiles.

PLoS ONE 6:e21230 (2011)
Publ. Version/Full Text Volltext DOI PMC
Open Access Gold
Creative Commons Lizenzvertrag
BACKGROUND: Human plasma and serum are widely used matrices in clinical and biological studies. However, different collecting procedures and the coagulation cascade influence concentrations of both proteins and metabolites in these matrices. The effects on metabolite concentration profiles have not been fully characterized. METHODOLOGY/PRINCIPAL FINDINGS: We analyzed the concentrations of 163 metabolites in plasma and serum samples collected simultaneously from 377 fasting individuals. To ensure data quality, 41 metabolites with low measurement stability were excluded from further analysis. In addition, plasma and corresponding serum samples from 83 individuals were re-measured in the same plates and mean correlation coefficients (r) of all metabolites between the duplicates were 0.83 and 0.80 in plasma and serum, respectively, indicating significantly better stability of plasma compared to serum (p = 0.01). Metabolite profiles from plasma and serum were clearly distinct with 104 metabolites showing significantly higher concentrations in serum. In particular, 9 metabolites showed relative concentration differences larger than 20%. Despite differences in absolute concentration between the two matrices, for most metabolites the overall correlation was high (mean r = 0.81±0.10), which reflects a proportional change in concentration. Furthermore, when two groups of individuals with different phenotypes were compared with each other using both matrices, more metabolites with significantly different concentrations could be identified in serum than in plasma. For example, when 51 type 2 diabetes (T2D) patients were compared with 326 non-T2D individuals, 15 more significantly different metabolites were found in serum, in addition to the 25 common to both matrices. CONCLUSIONS/SIGNIFICANCE: Our study shows that reproducibility was good in both plasma and serum, and better in plasma. Furthermore, as long as the same blood preparation procedure is used, either matrix should generate similar results in clinical and biological studies. The higher metabolite concentrations in serum, however, make it possible to provide more sensitive results in biomarker detection.
Impact Factor
Scopus SNIP
Web of Science
Times Cited
Scopus
Cited By
Altmetric
4.411
1.380
112
291
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords Chromatography; Metabolomics; Collection; Samples; Issues; Acid
Language english
Publication Year 2011
HGF-reported in Year 2011
ISSN (print) / ISBN 1932-6203
Journal PLoS ONE
Quellenangaben Volume: 6, Issue: 7, Pages: , Article Number: e21230 Supplement: ,
Publisher Public Library of Science (PLoS)
Publishing Place Lawrence, Kan.
Reviewing status Peer reviewed
POF-Topic(s) 30501 - Systemic Analysis of Genetic and Environmental Factors that Impact Health
30202 - Environmental Health

30505 - New Technologies for Biomedical Discoveries
30201 - Metabolic Health
30203 - Molecular Targets and Therapies
Research field(s) Genetics and Epidemiology

Enabling and Novel Technologies
PSP Element(s) G-504200-003
G-504000-001
G-503900-002
G-503700-001
G-505600-001
G-503090-001
G-500700-001
PubMed ID 21760889
Scopus ID 79960130240
Erfassungsdatum 2011-08-10