PuSH - Publication Server of Helmholtz Zentrum München

Dal Toso, L.* ; Chalampalakis, Z.* ; Buvat, I.* ; Comtat, C.* ; Cook, G.* ; Goh, V.* ; Schnabel, J.A. ; Marsden, P.K.*

Improved 3D tumour definition and quantification of uptake in simulated lung tumours using deep learning.

Phys. Med. Biol. 67:095013 (2022)
Publ. Version/Full Text DOI
Open Access Gold (Paid Option)
Creative Commons Lizenzvertrag
Objective. In clinical positron emission tomography (PET) imaging, quantification of radiotracer uptake in tumours is often performed using semi-quantitative measurements such as the standardised uptake value (SUV). For small objects, the accuracy of SUV estimates is limited by the noise properties of PET images and the partial volume effect. There is need for methods that provide more accurate and reproducible quantification of radiotracer uptake. Approach. In this work, we present a deep learning approach with the aim of improving quantification of lung tumour radiotracer uptake and tumour shape definition. A set of simulated tumours, assigned with 'ground truth' radiotracer distributions, are used to generate realistic PET raw data which are then reconstructed into PET images. In this work, the ground truth images are generated by placing simulated tumours characterised by different sizes and activity distributions in the left lung of an anthropomorphic phantom. These images are then used as input to an analytical simulator to simulate realistic raw PET data. The PET images reconstructed from the simulated raw data and the corresponding ground truth images are used to train a 3D convolutional neural network. Results. When tested on an unseen set of reconstructed PET phantom images, the network yields improved estimates of the corresponding ground truth. The same network is then applied to reconstructed PET data generated with different point spread functions. Overall the network is able to recover better defined tumour shapes and improved estimates of tumour maximum and median activities. Significance. Our results suggest that the proposed approach, trained on data simulated with one scanner geometry, has the potential to restore PET data acquired with different scanners.
Altmetric
Additional Metrics?
Edit extra informations Login
Publication type Article: Journal article
Document type Scientific Article
Corresponding Author
Keywords Pet ; Cnn ; Quantification
ISSN (print) / ISBN 0031-9155
e-ISSN 1361-6560
Quellenangaben Volume: 67, Issue: 9, Pages: , Article Number: 095013 Supplement: ,
Publisher Institute of Physics Publishing (IOP)
Publishing Place Bristol
Non-patent literature Publications
Reviewing status Peer reviewed
Institute(s) Institute for Machine Learning in Biomed Imaging (IML)
Grants Cancer ResearchUKNational Cancer Imaging Translational Accelerator Award
General Electric
National Institute for Health Research (NIHR)
UK Research & Innovation (UKRI) Engineering & Physical Sciences Research Council (EPSRC)
SKA South Africa