PuSH - Publication Server of Helmholtz Zentrum München

Karusheva, Y.* ; Ratcliff, M.* ; Mörseburg, A.* ; Barker, P.* ; Melvin, A.* ; Sattar, N.* ; Burling, K.* ; Backmark, A.* ; Roth, R.* ; Jermutus, L.* ; Guiu-Jurado, E. ; Blüher, M. ; Welsh, P.* ; Hyvönen, M.E.* ; O'Rahilly, S.*

The common H202D variant in GDF-15 does not affect its bioactivity but can significantly interfere with measurement of Its circulating levels.

J. Appl. Lab. Med. 7, 1388-1400 (2022)
Postprint Research data DOI PMC
Open Access Hybrid
Creative Commons Lizenzvertrag
BACKGROUND: There is growing interest in the measurement of growth differentiation factor 15 (GDF-15) in a range of disorders associated with cachexia. We undertook studies to determine whether a common histidine (H) to aspartate (D) variant at position 202 in the pro-peptide (position 6 in the mature peptide) interfered with its detection by 3 of the most commonly used immunoassays. METHODS: Three synthetic GDF-15-forms (HH homo-, HD hetero-, and DD-homodimers) were measured after serial dilution using Roche Elecsys®, R&D QuantikineTM ELISA, and MSD R&D DuoSet® immunoassays. GDF-15 concentrations were measured by the Roche and the MSD R&D immunoassays in 173 genotyped participants (61 HH homozygotes, 59 HD heterozygotes, and 53 DD homozygotes). For the comparative statistical analyses of the GDF-15 concentrations, we used non-parametric tests, in particular Bland-Altman difference (bias) plots and Passing-Bablok regression. The bioactivity of the 2 different homodimers was compared in a cell-based assay in HEK293S-SRF-RET/GFRAL cells. RESULTS: The Roche assay detected H- and D-containing peptides similarly but the R&D reagents (Quantikine and DuoSet) consistently underreported GDF-15 concentrations in the presence of the D variant. DD dimers had recoveries of approximately 45% while HD dimers recoveries were 62% to 78%. In human serum samples, the GDF-15 concentrations reported by the R&D assay were a median of 4% lower for HH, a median of 36% lower for HD, and a median of 61% lower for DD compared to the Roche assay. The bioactivities of the HH and DD peptides were indistinguishable. CONCLUSIONS: The D variant of GDF-15 substantially affects its measurement by a commonly used immunoassay, a finding that has clear implications for its interpretation in research and clinical settings.
Impact Factor
Scopus SNIP
Altmetric
0.530
0.478
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Language english
Publication Year 2022
HGF-reported in Year 2022
ISSN (print) / ISBN 2576-9456
e-ISSN 2475-7241
Quellenangaben Volume: 7, Issue: 6, Pages: 1388-1400 Article Number: , Supplement: ,
Publisher Oxford University Press
Reviewing status Peer reviewed
Institute(s) Helmholtz Institute for Metabolism, Obesity and Vascular Research (HI-MAG)
POF-Topic(s) 30201 - Metabolic Health
Research field(s) Helmholtz Diabetes Center
PSP Element(s) G-555600-001
G-506501-001
Scopus ID 85141005456
PubMed ID 35796717
Erfassungsdatum 2022-10-31