PuSH - Publication Server of Helmholtz Zentrum München

Harder, F.N.* ; Lohöfer, F.K.* ; Kaissis, G.* ; Zoellner, C.* ; Kamal, O.* ; Katemann, C.* ; Hock, A.* ; Senegas, J.* ; Peeters, J.M.* ; Rummeny, E.J.* ; Karampinos, D.C.* ; Braren, R.F.*

Camera-based respiratory triggering improves the image quality of 3D magnetic resonance cholangiopancreatography.

Eur. J. Radiol. 120:108675 (2019)
DOI PMC
Open Access Green as soon as Postprint is submitted to ZB.
PURPOSE: To evaluate the performance of a novel camera-based breathing navigation system in respiratory-triggered (CRT) 3D-magnetic resonance cholangiopancreatography (MRCP) at 3T MRI. METHODS: Two 3D-MRCP data sets were acquired subsequently within one imaging session with traditional respiratory belt- (BRT) or camera- (CRT) based triggering in 28 patients. Overall image quality, blurring, motion artifacts and discernibility of the pancreaticobiliary tree (PBT) structures were scored on a 4-point scale retrospectively by 2 radiologists. The contrast ratio between the common bile duct and its adjacent tissue was measured by region-of-interest (ROI) analysis. The signal intensity increase at the duct boundaries was quantified by line profiles to objectify blurring and motion artifacts. The extracted respiratory signal curves were analyzed for signal quality and trigger timing. RESULTS: Total scan time was 72 s for both acquisitions. CRT yielded significantly better ratings in image quality, background suppression, blurring and discernibility of PBT structures compared to BRT. Contrast ratios were significantly higher in CRT (0.94 ± 0.03) than in BRT (0.93 ± 0.03) exams; paired t test P = 0.0017. Line profile slopes through the common bile duct revealed significantly higher values in CRT (42.23 ± 8.74% of maximum intensity/mm) compared to BRT (36.06 ± 8.96% of maximum intensity/mm; paired t test P < 0.0001). Camera-derived respiratory signal curves showed a higher SNR, lower standard deviation of the signal amplitude and less incorrect triggering than the respiratory belt-derived respiratory signal curves. CONCLUSION: Camera-based respiratory triggering significantly improves image quality of 3D-MRCP compared to conventional respiratory belt triggering.
Impact Factor
Scopus SNIP
Altmetric
2.948
1.170
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords Biliary Tract ; Diagnostic Techniques And Procedures ; Magnetic Resonance Cholangiopancreatography ; Magnetic Resonance Imaging ; Pancreatic Ducts
Language english
Publication Year 2019
HGF-reported in Year 2019
ISSN (print) / ISBN 0720-048X
e-ISSN 0720-048X
Quellenangaben Volume: 120, Issue: , Pages: , Article Number: 108675 Supplement: ,
Publisher Elsevier
Reviewing status Peer reviewed
POF-Topic(s) 30205 - Bioengineering and Digital Health
Research field(s) Enabling and Novel Technologies
PSP Element(s) G-530014-001
PubMed ID 31585303
Erfassungsdatum 2022-09-13