PuSH - Publication Server of Helmholtz Zentrum München

Wittig, T. ; Sabanov, A.* ; Schmidt, A.* ; Scheinert, D.* ; Steiner, S. ; Branzan, D.

Feasibility and safety of percutaneous axillary artery access in a prospective series of 100 complex aortic and aortoiliac interventions.

J. Clin. Med. 12:11 (2023)
DOI PMC
Creative Commons Lizenzvertrag
Open Access Gold as soon as Publ. Version/Full Text is submitted to ZB.
We aimed to review the feasibility and safe use of the percutaneous axillary artery (AxA, 100 patients) approach for endovascular repair (ER) of thoraco-abdominal aortic aneurysms (TAAA, 90 patients) using fenestrated, branched, and chimney stent grafts and other complex endovascular procedures (10 patients) necessitating AxA access. Percutaneous puncture of the AxA in its third segment was performed using sheaths sized between 6 to 14F. For closing puncture sites greater than 8F, two Perclose ProGlide percutaneous vascular closure devices (PVCDs) (Abbott Vascular, Santa Clara, CA, USA) were deployed in the pre-close technique. The median maximum diameter of the AxA in the third segment was 7.27 mm (range 4.50-10.80). Device success, defined as successful hemostasis by PVCD, was reported in 92 patients (92.0%). As recently reported results in the first 40 patients suggested that adverse events, including vessel stenosis or occlusion, occurred only in cases with a diameter of the AxA < 5 mm, in all subsequent 60 cases AxA access was restricted to a vessel diameter ≥ 5 mm. In this late group, no hemodynamic impairment of the AxA occurred except in six early cases below this diameter threshold, all of which could be repaired by endovascular measures. Overall mortality at 30 days was 8%. In conclusion, percutaneous approach of the AxA in its third segment is feasible and represents a safe alternative access to open access for complex endovascular aorto-iliac procedures. Complications are rare, especially if the maximum diameter of the access vessel (AxA) is ≥5 mm.
Altmetric
Additional Metrics?
Edit extra informations Login
Publication type Article: Journal article
Document type Scientific Article
Corresponding Author
Keywords Aortic Aneurysm ; Complex Endovascular Aneurysm Repair ; Endovascular Intervention ; Percutaneous Closure Device ; Upper Extremity Access
ISSN (print) / ISBN 2077-0383
e-ISSN 2077-0383
Quellenangaben Volume: 12, Issue: 5, Pages: , Article Number: 11 Supplement: ,
Publisher MDPI
Publishing Place Basel
Non-patent literature Publications
Reviewing status Peer reviewed
Institute(s) Helmholtz Institute for Metabolism, Obesity and Vascular Research (HI-MAG)
Grants Leipzig University - German Research Foundation