PuSH - Publication Server of Helmholtz Zentrum München

Schuppert, C.* ; Rospleszcz, S. ; Hirsch, J.G.* ; Hoinkiss, D.C.* ; Köhn, A.* ; von Krüchten, R.* ; Russe, M.F.* ; Keil, T.* ; Krist, L.* ; Schmidt, B.* ; Michels, K.B.* ; Schipf, S.* ; Brenner, H.* ; Kröncke, T.J.* ; Pischon, T.* ; Niendorf, T.* ; Schulz-Menger, J.* ; Forsting, M.* ; Völzke, H.* ; Hosten, N.* ; Bülow, R.* ; Zaitsev, M.A.* ; Kauczor, H.U.* ; Bamberg, F.* ; Günther, M.* ; Schlett, C.L.*

Automated image quality assessment for selecting among multiple magnetic resonance image acquisitions in the German National Cohort study.

Sci. Rep. 13:22745 (2023)
Publ. Version/Full Text DOI PMC
Open Access Gold
Creative Commons Lizenzvertrag
In magnetic resonance imaging (MRI), the perception of substandard image quality may prompt repetition of the respective image acquisition protocol. Subsequently selecting the preferred high-quality image data from a series of acquisitions can be challenging. An automated workflow may facilitate and improve this selection. We therefore aimed to investigate the applicability of an automated image quality assessment for the prediction of the subjectively preferred image acquisition. Our analysis included data from 11,347 participants with whole-body MRI examinations performed as part of the ongoing prospective multi-center German National Cohort (NAKO) study. Trained radiologic technologists repeated any of the twelve examination protocols due to induced setup errors and/or subjectively unsatisfactory image quality and chose a preferred acquisition from the resultant series. Up to 11 quantitative image quality parameters were automatically derived from all acquisitions. Regularized regression and standard estimates of diagnostic accuracy were calculated. Controlling for setup variations in 2342 series of two or more acquisitions, technologists preferred the repetition over the initial acquisition in 1116 of 1396 series in which the initial setup was retained (79.9%, range across protocols: 73-100%). Image quality parameters then commonly showed statistically significant differences between chosen and discarded acquisitions. In regularized regression across all protocols, 'structured noise maximum' was the strongest predictor for the technologists' choice, followed by 'N/2 ghosting average'. Combinations of the automatically derived parameters provided an area under the ROC curve between 0.51 and 0.74 for the prediction of the technologists' choice. It is concluded that automated image quality assessment can, despite considerable performance differences between protocols and anatomical regions, contribute substantially to identifying the subjective preference in a series of MRI acquisitions and thus provide effective decision support to readers.
Impact Factor
Scopus SNIP
Altmetric
4.600
0.000
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords Design
Language english
Publication Year 2023
HGF-reported in Year 2023
ISSN (print) / ISBN 2045-2322
e-ISSN 2045-2322
Quellenangaben Volume: 13, Issue: 1, Pages: , Article Number: 22745 Supplement: ,
Publisher Nature Publishing Group
Publishing Place London
Reviewing status Peer reviewed
Institute(s) Institute of Epidemiology (EPI)
POF-Topic(s) 30202 - Environmental Health
Research field(s) Genetics and Epidemiology
PSP Element(s) G-504000-010
Grants Helmholtz Association
Federal Ministry of Education and Research (BMBF)
Universittsklinikum Freiburg (8975)
Scopus ID 85180253339
PubMed ID 38123791
Erfassungsdatum 2024-01-09