Smart chip cards are a promising material in retrospective dosimetry due to their high collectability with low replacement cost. In this study, dose reconstruction using OSL at elevated temperatures for various chip cards was investigated. The approximate spectral emission of the chip cards was determined through a comparison of radiation-induced and intrinsic background TL signals using different detection filters. In the OSL decay curve, a fast component (0.0–0.4 s) was integrated to avoid high intrinsic background signals. To minimize sensitivity changes due to heat treatment, a protocol to measure OSL at 100 °C was developed and the data were compared with those from a similar protocol for OSL measured at room temperature. In the 0.1 - 5 Gy range, linear and power functions were fitted for room temperature and 100 °C OSL protocols, respectively. The minimum detectable dose was evaluated immediately after exposure, with values of 25 mGy for room temperature and 240 mGy for 100 °C OSL being determined. Signal fading was measured up to 30 days after irradiation for the investigated protocols. A dose recovery test was made 10 days after irradiation using various chip cards, and the 100 °C OSL protocol produced more reliable results than the room temperature OSL protocol. As a result, the study emphasizes the necessity of further investigation of OSL at high temperatures using chip cards.
Impact Factor
Scopus SNIP
Altmetric
2.800
0.971
Tags
Annotations
Special Publikation
Hide on homepage

Edit extra information
Edit own tags
Private
Edit own annotation
Private
Hide on publication lists
on hompage
Mark as special
publikation
Publication type Article: Journal article
Document type Scientific Article
Keywords Dose Recovery Test ; Osl At Elevated Temperature ; Retrospective Dosimetry ; Smart Chip Card; Optically Stimulated Luminescence; Electronic Components; Mobile Phones; Thermoluminescence; Dependence
Language english
Publication Year 2024
HGF-reported in Year 2024
ISSN (print) / ISBN 0969-806X
e-ISSN 1879-0895
Quellenangaben Volume: 217, Issue: , Pages: , Article Number: 111520 Supplement: ,
Publisher Elsevier
Publishing Place The Boulevard, Langford Lane, Kidlington, Oxford Ox5 1gb, England
Reviewing status Peer reviewed
POF-Topic(s) 30203 - Molecular Targets and Therapies
Research field(s) Radiation Sciences
PSP Element(s) G-501391-001
Grants EURADOS young scientist grant (2019)
Korea Atomic Energy Research Institute
National Research Foundation of Korea (NRF) - Korean government (Ministry of Science and ICT)
Scopus ID 85182594984
Erfassungsdatum 2024-01-29