Abou-Elkacem, L.* ; Björn, S. ; Doleschel, D.* ; Ntziachristos, V. ; Schulz, R.B. ; Hoffman, R.M.* ; Kiessling, F.* ; Lederle, W.*

High accuracy of mesoscopic epi-fluorescence tomography for non-invasive quantitative volume determination of fluorescent protein-expressing tumours in mice.

Eur. Radiol. 22, 1955-1962 (2012)
DOI PMC
Open Access Green as soon as Postprint is submitted to ZB.
To compare mesoscopic epi-fluorescence tomography (MEFT) and EPRI-illumination reflectance imaging (EPRI) for quantitative tumour size assessment in mice. Tumour xenografts of green/red fluorescent protein (GFP/RFP)-expressing colon cancer cells were measured using MEFT, EPRI, ultrasound (US) and micro computed tomography (mu CT) at day 14 post-injection (n = 6). Results from MEFT and EPRI were correlated with each other and with US and mu CT (reference methods). Tumour volumes were measured ex vivo by GFP and RFP fluorescence imaging on cryoslices and compared with the in vivo measurements. High correlation and congruency were observed between MEFT, US and mu CT (MEFT/US: GFP: r (2) = 0.96; RFP: r (2) = 0.97, both P < 0.05; MEFT/mu CT: GFP: r (2) = 0.93; RFP: r (2) = 0.90; both P < 0.05). Additionally, in vivo MEFT data were highly correlated and congruent with ex vivo cryoslice imaging results (GFP: r (2) = 0.96; RFP: r (2) = 0.99; both P < 0.05). In comparison, EPRI significantly overestimated tumour volumes (P < 0.05), although there was a significant correlation with US and mu CT (EPRI/US: GFP: r (2) = 0.95; RFP: r (2) = 0.94; both P < 0.05; EPRI/mu CT GFP: r (2) = 0.86; RFP: r (2) = 0.86; both P < 0.05). Fluorescence distribution reconstruction using MEFT affords highly accurate three-dimensional (3D) tumour volume data showing superior accuracy compared to EPRI. Thus, MEFT is a very suitable technique for quantitatively assessing fluorescence distribution in superficial tumours at high spatial resolution. aEuro cent Mesoscopic epi-fluorescence tomography (MEFT) is an important new molecular imaging technique. aEuro cent MEFT allows accurate size determination of superficial tumours with high resolution. aEuro cent MEFT is a suitable technique for longitudinal assessment of tumour growth. aEuro cent MEFT allows 3D reconstruction and quantification of fluorescence distributions.
Altmetric
Additional Metrics?
Edit extra informations Login
Publication type Article: Journal article
Document type Scientific Article
Corresponding Author
Keywords Mesoscopic Epi-fluorescence Tomography ; Micro Computed Tomography ; Tumour Volume ; Ultrasound ; Red/green Fluorescent Protein; IN-VIVO; CANCER
ISSN (print) / ISBN 0938-7994
e-ISSN 1432-1084
Quellenangaben Volume: 22, Issue: 9, Pages: 1955-1962 Article Number: , Supplement: ,
Publisher Springer
Non-patent literature Publications
Reviewing status Peer reviewed