    Systematic survey of the dose enhancement in tissue-equivalent materials facing medium- and high-Z backscatterers exposed to X-rays with energies from 5 to 250 keV.
        
        Radiat. Environ. Biophys. 53, 437-453 (2014)
    
    
    
				The present study has been inspired by the results of earlier dose measurements in tissue-equivalent materials adjacent to thin foils of aluminum, copper, tin, gold, and lead. Large dose enhancements have been observed in low-Z materials near the interface when this ensemble was irradiated with X-rays of qualities known from diagnostic radiology. The excess doses have been attributed to photo-, Compton, and Auger electrons released from the metal surfaces. Correspondingly, high enhancements of biological effects have been observed in single cell layers arranged close to gold surfaces. The objective of the present work is to systematically survey, by calculation, the values of the dose enhancement in low-Z media facing backscattering materials with a variety of atomic numbers and over a large range of photon energies. Further parameters to be varied are the distance of the point of interest from the interface and the kind of the low-Z material. The voluminous calculations have been performed using the PHOTCOEF algorithm, a proven set of interpolation functions fitted to long-established Monte Carlo results, for primary photon energies between 5 and 250 keV and for atomic numbers varying over the periodic system up to Z = 100. The calculated results correlate well with our previous experimental results. It is shown that the values of the dose enhancement (a) vary strongly in dependence upon Z and photon energy; (b) have maxima in the energy region from 40 to 60 keV, determined by the K and L edges of the backscattering materials; and (c) are valued up to about 130 for "International Commission on Radiological Protection (ICRP) soft tissue" (soft tissue composition recommended by the ICRP) as the adjacent low-Z material. Maximum dose enhancement associated with the L edge occurs for materials with atomic numbers between 50 and 60, e.g., barium (Z = 56) and iodine (Z = 53). Such materials typically serve as contrast media in medical X-ray diagnostics. The gradual reduction in the dose enhancement with increasing distance from the material interface, owed to the limited ranges of the emitted secondary electrons, has been documented in detail. The discussion is devoted to practical radiological aspects of the dose enhancement phenomenon. Cytogenetic effects in cell layers closely proximate to surfaces of medium-Z materials might vary over two orders of magnitude, because the dose enhancement is accompanied by the earlier observed about twofold increase in the low-dose RBEM at a tissue-to-gold interface.
			
			
		Impact Factor
					Scopus SNIP
					Web of Science
Times Cited
					
					
					Times Cited
Altmetric
					
				1.582
					0.977
					1
					
					
					
				Anmerkungen
				
					
						 
						
					
				
			
				
			
				Besondere Publikation
				
					
						 
					
				
			
			
			
				Auf Hompepage verbergern
				
					
						 
					
				
			
			
        Publikationstyp
        Artikel: Journalartikel
    
 
    
        Dokumenttyp
        Wissenschaftlicher Artikel
    
 
     
    
    
        Schlagwörter
        Dose Enhancement ; Material Interfaces ; Contrast Agents ; X-rays ; Backscattered Secondary Electrons; Atomic-number Interfaces; Megavoltage Photon Beams; Radiation-therapy Gnrt; Monte-carlo; Secondary Electrons; Gold Nanoparticles; Contrast Agents; Scattered Radiation; Neck Radiotherapy; Perturbation
    
 
     
    
    
        Sprache
        englisch
    
 
    
        Veröffentlichungsjahr
        2014
    
 
     
    
        HGF-Berichtsjahr
        2014
    
 
    
    
        ISSN (print) / ISBN
        0301-634X
    
 
    
        e-ISSN
        1432-2099
    
 
     
     
     
	     
	 
	 
    
        Zeitschrift
        Radiation and Environmental Biophysics
    
 
		
    
        Quellenangaben
        
	    Band: 53,  
	    Heft: 2,  
	    Seiten: 437-453 
	    
	    
	
    
 
  
         
        
            Verlag
            Springer
        
 
        
            Verlagsort
            New York
        
 
	
         
         
         
         
         
	
         
         
         
    
         
         
         
         
         
         
         
    
        Begutachtungsstatus
        Peer reviewed
    
 
     
    
        POF Topic(s)
        30504 - Mechanisms of Genetic and Environmental Influences on Health and Disease
    
 
    
        Forschungsfeld(er)
        Radiation Sciences
    
 
    
        PSP-Element(e)
        G-503600-002
    
 
     
     	
    
    
        WOS ID
        WOS:000334998200022
    
    
        Scopus ID
        84902544637
    
    
        Erfassungsdatum
        2014-06-02